CPC7582
1.6.3 Ringing Switch, SW4
Parameter
Conditions
Symbol
Minimum
Typical
Maximum
Unit
Off-state leakage current
V
V
(differential) = -255 V to +210 V
(differential) = +255 V to -210 V
SW
+25° C
+85° C
0.05
0.1
SW
V
V
(differential) = -270 V to +210 V
(differential) = +270 V to -210 V
SW
I
1
μA
SW
SW
V
V
(differential) = -245 V to +210 V
(differential) = +245 V to -210 V
SW
-40° C
0.05
SW
I
(on) = 1 mA
V
On Voltage
1.5
0.1
-
3
V
SW
SW
-
Ringing generator
current to ground
Ringing switches on, inputs set for
ringing mode
I
0.25
150
mA
mA
RINGING
I
On steady-state current* Inputs set for ringing mode
SW
Ringing switches on, all other switches
off, apply 1 kV 10 x 1000 μs pulse,
with appropriate protection in place.
Surge current*
Release current
-
-
2
A
I
-
300
10
-
μA
RINGING
R
I
(on) = 70 mA, 80 mA
R
15
Ω
ON
SW
ON
Logic input to switch output isolation
V
(R
SW RINGING LINE
, R ) = 320 V, logic
+25° C
+85° C
0.1
0.3
inputs = gnd
(R
V
, R ) = 330 V, logic
SW RINGING LINE
I
-
1
-
μA
SW
inputs = gnd
(R
V
, R ) = 310 V, logic
SW RINGING LINE
-40° C
0.1
inputs = gnd
dv/dt sensitivity
-
-
200
V/μs
*Secondary protection and ringing source current limiting must prevent exceeding this parameter.
R05
www.clare.com
7