CPC1465  
2. Functional Description  
2.1 Introduction  
operational characteristics if the tip and ring leads are  
reversed.  
The CPC1465 can be used for a number of designs  
requiring a dc hold circuit such as SHDSL modem and  
ISDN NT1 terminal applications. Typical SHDSL  
applications will use a circuit design similar to the one  
shown in Figure 10‚ “Typical ISDN NT1 Application  
Diagram” on page 9 while the typical ISDN NT1 circuit  
design will be similar to the one shown in Figure 10‚  
Typical ISDN NT1 Application Diagram” on page 9.  
2.4 State Transitions  
The dc tip to ring voltage-current characteristics of the  
CPC1465 are shown in Figure 2‚ “I-V Requirements  
Template, 0 V to 50 V”, and in Figure 3‚ “I-V  
Requirements Template, 0 V to 250 V” on page 5.  
The DC Termination IC performs two functions in an  
ISDN NT1 terminal; as an electronic inductor providing  
a low impedance dc termination with a high  
impedance ac termination, and second as part of the  
dc signalling system for automated line testing  
capability. The CPC1465 meets or exceeds the  
requirements for an NT1 dc termination as described  
in ANSI T1.601-1991.  
Transition timings are illustrated in Figure 7‚ “Applied  
Waveform for Activation Test”, and in Figure 8‚  
“Applied Waveform for Deactivation Test”. The test  
configuration for these timings is given in Figure 6‚  
Test Circuit for Activate and Deactivate Times”. All  
timing figures are located on page 7.  
State transition timings are set by the 1 μF capacitor  
connected between the TC and COM pins.  
Whereas the SHDSL modem application does not  
have a signalling requirement, the signaling function  
provides an excellent method to monitor for the loss of  
sealing current. Generally, loss of sealing current in an  
SHDSL application indicates loop loss.  
2.4.1 Activation - On-State  
Application of battery voltage to the loop causes the  
CPC1465 to conduct whenever the voltage exceeds  
approximately 35 V. With application of sufficient  
voltage applied across the tip and ring terminals, the  
CPC1465 will initially conduct a nominal 150 μA of  
sealing current for approximately 20 ms prior to  
activation. Once activated, the CPC1465 will remain in  
the on state for as long as the loop current exceeds a  
nominal 0.5 mA.  
As can be seen in the application circuit in Figure 1 on  
page 1, CPC1465 designs require few external  
components. For the most basic design, all that is  
needed is a circuit protector, two resistors and a  
capacitor.  
The CPC1465 turn-on timing circuit assures device  
activation will occur within 50 ms of an applied voltage  
greater than 43.5 V but not within the first 3 ms.  
2.2 Surge Protection  
Although the CPC1465 is current limited, it is not an  
over-voltage surge protector. To protect the CPC1465  
against destructive over-voltage transients, Clare  
recommends the use of a crowbar-type surge  
protector that limits the surge voltage seen by the  
CPC1465 to 250 V. The protection device must be  
able to withstand the surge requirements specified by  
the appropriate governing agency in regions where  
the product will be deployed. Teccor, Inc. and Bourns,  
Inc. make suitable surge protectors for most  
applications. Devices such as Teccor’s P1800SC or  
P2000SC Sidactors and Bourns’ TISP4220H3 or  
TISP4240H3 thyristors should provide suitable  
protection.  
2.4.2 Deactivation - Off-State  
While the CPC1465 activation protocol is based on an  
initial minimum voltage level, deactivation is based on  
a diminished sealing current level. Deactivation occurs  
when the nominal sealing current level drops below  
0.5 mA with guaranteed deactivation occurring for  
sealing current levels less than 0.1 mA  
The turn-off timing circuit deactivates the sealing  
current hold circuit when 1 mA of sealing current has  
been removed for 100 ms but ignores periods of loss  
up to 3 ms.  
2.3 Bridge Rectifier  
The bridge rectifier in the CPC1465 ensures that the  
device is polarity insensitive and provides consistent  
10  
www.clare.com  
R02  