CPC1002N
Absolute Maximum Ratings (@ 25˚ C)
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter
Ratings
Units
V
Blocking Voltage
Reverse Input Voltage
60
5
V
Input Control Current
Peak (10ms)
50
1
mA
A
Input Power Dissipation
70
400
1500
-40 to +85
-40 to +125
mW
mW
Vrms
°C
Total Power Dissipation 1
Isolation Voltage Input to Output
Operational Temperature
Storage Temperature
°C
1
Derate Linearly 3.33 mw / º
C
Electrical Characteristics
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Output Characteristics @ 25°C
Load Current, Continuous 1
Peak Load Current
IF=2mA
10ms
IL=100mA
VL=60V
700
1
0.55
1
mA
Arms
Ω
On-Resistance 2
Off-State Leakage Current
Switching Speeds
Turn-On
Turn-Off
Output Capacitance
Capacitance Input to Output
Input Characteristics @ 25°C
Input Control Current 3
Input Dropout Current
Input Voltage Drop
µA
IF=3mA
TON
5
ms
TOFF
COUT
25
1
2
ms
pF
pF
700mA
IF=5mA
VR=5V
IF
IF
VF
IR
2
0.3
0.9
1.2
1.4
10
mA
mA
V
Reverse Input Current
µA
1
Load current derates linearly from 7
Measurement taken within 1 sec
80oC.
2
3
For applications requiring high temperature operation (greater than 60oC) an LED drive current of 3mA is recommended.
R00B
2