CS42432
Binary Code
0111 1111
···
Volume Setting
+24 dB
···
0011 0000
···
+24 dB
···
0000 0000
1111 1111
1111 1110
···
0 dB
-0.5 dB
-1 dB
···
1000 0000
-64 dB
Table 7. Example AIN Volume Settings
7.12 ADC Channel Invert (Address 17h)
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
INV_AIN4
INV_AIN3
INV_AIN2
INV_AIN1
7.12.1 Invert Signal Polarity (INV_AINX)
Default = 0
0 - Disabled
1 - Enabled
Function:
When enabled, these bits will invert the signal polarity of their respective channels.
7.13 Status (Address 19h) (Read Only)
7
6
5
4
3
2
1
0
Reserved
Reserved
Reserved
Reserved
CLK Error
Reserved
ADC2_OVFL
ADC1_OVFL
For all bits in this register, a “1” means the associated error condition has occurred at least once since the
register was last read. A”0” means the associated error condition has NOT occurred since the last reading
of the register. Reading the register resets all bits to 0. Status bits that are masked off in the associated
mask register will always be “0” in this register.
7.13.1 CLOCK ERROR (CLK ERROR)
Default = x
Function:
Indicates an invalid MCLK to FS ratio. This status flag is set to “Level Active Mode” and becomes active
during the error condition. See “System Clocking” on page 31 for valid clock ratios.
7.13.2 ADC Overflow (ADCX_OVFL)
Default = x
Function:
Indicates that there is an over-range condition anywhere in the CS42432 ADC signal path of each of the
associated ADC’s.
46
DS673F1