CS3001
CS3002
1. CHARACTERISTICS AND SPECIFICATIONS
ELECTRICAL CHARACTERISTICS V+ = +5 V, V- = 0V, VCM = 2.5 V (Note 1)
CS3001/CS3002
Parameter
Min
Typ
-
Max
±10
Unit
µV
Input Offset Voltage
(Note 2)
(Note 2)
•
•
-
-
Average Input Offset Drift
±0.01
(Note 3)
±0.05
µV/ºC
Long Term Input Offset Voltage Stability
Input Bias Current
T = 25º C
-
-
±100
-
-
pA
pA
A
•
•
±1000
Input Offset Current
T = 25º C
-
-
±200
-
-
pA
pA
A
±2000
Input Noise Voltage Density R = 100 Ω, f = 1 Hz
-
-
6
6
nV/ Hz
nV/ Hz
S
0
R = 100 Ω, f = 1 kHz
S
0
Input Noise Voltage
0.1 to 10 Hz
-
-
125
100
nV
p-p
Input Noise Current Density f = 1 Hz
fA/ Hz
pA
0
Input Noise Current
0.1 to 10 Hz
-
1.9
-
p-p
Input Common Mode Voltage Range
Common Mode Rejection Ratio (dc)
Power Supply Rejection Ratio
•
•
•
•
-0.1
115
120
200
(V+)-1.25
V
(Note 4)
(Note 5)
120
136
300
-
-
-
dB
dB
dB
Large Signal Voltage Gain R = 2 kΩ to V+/2
L
Output Voltage Swing
R = 2 kΩ to V+/2
•
+4.7
-
-
V
V
L
R = 100 kΩ to V+/2
+4.99
L
Slew Rate
R = 2 k, 100 pF
5
-
-
V/µs
µs
L
Overload Recovery Time
Supply Current
-
100
CS3001
CS3002
(Note 6)
•
•
•
-
-
2.1
3.6
2.8
4.8
15
mA
mA
µA
PWDN active (CS3001 Only)
•
•
(V+) -1.0
-
-
-
V
PWDN Threshold
Start-up Time
(Note 6)
(Note 7)
9
12
ms
Notes: 1. Symbol “•” denotes specification applies over -40 to +85 ° C.
2. This parameter is guaranteed by design and laboratory characterization. Thermocouple effects prohibit
accurate measurement of these parameters in automatic test systems.
3. 1000-hour life test data @ 125 °C indicates randomly distributed variation approximately equal to
measurement repeatability of 1 µV.
4. Measured within the specified common mode range limits.
5. Guaranteed within the output limits of (V+ -0.3 V) to (V- +0.3 V). Tested with proprietary production test
method.
6. PWDN input has an internal pullup resistor to V+ of approximately 800 kΩ and is the major source of
current consumption when PWDN is active low.
7. The device has a controlled start-up behavior due to its complex open loop gain characteristics. Start-
up time applies when supply voltage is applied or when PDWN is released.
DS490F9
3