CS4525  
9.10 Volume and 2-Way Cross-Over Configuration (Address 55h)  
7
6
5
4
3
2
1
0
SZCMode1  
SZCMode0  
Mute50/50  
AutoMute  
En2Way  
2WayFreq2  
2WayFreq1  
2WayFreq0  
9.10.1 Soft Ramp and Zero Cross Control (SZCMode[1:0])  
Default = 10  
Function:  
Sets the soft ramp and zero crossing detection modes by which volume and muting changes will be im-  
plemented.  
SZCMode[1:0] Setting  
00 ........................................Immediate Change  
When immediate change is selected, all level changes will take effect immediately in one step.  
01 ........................................Zero Cross  
Zero cross dictates that signal level changes, both muting and attenuation, will occur on a signal  
Soft Ramp & Zero Crossing Mode  
zero crossing to minimize audible artifacts. The requested level change will occur after a timeout  
period (approximately 18.7 ms for a PWM switch rate of 384/768 kHz and 17.0 ms for a PWM  
switch rate of 421.875/843.75 kHz) if the signal does not encounter a zero crossing. The zero cross  
function is independently monitored and implemented for each channel.  
10 ........................................Soft Ramp  
Soft ramp allows level changes, both muting and attenuation, to be implemented by incrementally  
ramping, in ½ dB steps, from the current level to the new level at a rate of ½ dB per 4 sample peri-  
ods for 32, 44.1, and 48 kHz, and ½ dB per 8 sample periods for 96 kHz.  
11.........................................Soft Ramp on Zero Cross  
Soft ramp on zero cross dictates that signal level changes, both muting and attenuation, will occur in  
½ dB steps and be implemented on a signal zero crossing. The ½ dB level change will occur after a  
timeout period (approximately 18.7 ms for a PWM switch rate of 384/768 kHz and 17.0 ms for a  
PWM switch rate of 421.875/843.75 kHz) if the signal does not encounter a zero crossing. The zero  
cross function is independently monitored and implemented for each channel.  
9.10.2 Enable 50% Duty Cycle for Mute Condition (Mute50/50)  
Default = 0  
Function:  
When set, the amplifiers will output a non-modulated 50%-duty-cycle signal for all mute conditions. This  
bit does not cause a mute condition to occur. The Mute50/50 bit only defines operation during a normal  
mute condition.  
Mute50/50 Setting  
50% Duty Cycle Mute State  
0 ..........................................50% duty cycle for mute conditions disabled.  
1 ..........................................50% duty cycle for mute conditions enabled.  
9.10.3 Auto-Mute (AutoMute)  
Default = 1  
Function:  
When enabled, the outputs of the CS4525 will mute following the reception of 8192 consecutive audio  
samples of static 0 or -1. A single sample of non-static data will release the mute. Detection and muting  
is done independently for each channel. See “Volume and Muting Control” on page 36 for more informa-  
tion.  
AutoMute Setting  
AutoMute State  
0 ..........................................Auto-mute on static 0’s or -1’s disabled.  
1 ..........................................Auto-mute on static 0’s or -1’s enabled.  