欢迎访问ic37.com |
会员登录 免费注册
发布采购

CDB5471 参数 Datasheet PDF下载

CDB5471图片预览
型号: CDB5471
PDF下载: 下载PDF文件 查看货源
内容描述: 评估板和软件 [Evaluation Board and Software]
分类和应用:
文件页数/大小: 26 页 / 1246 K
品牌: CIRRUS [ CIRRUS LOGIC ]
 浏览型号CDB5471的Datasheet PDF文件第13页浏览型号CDB5471的Datasheet PDF文件第14页浏览型号CDB5471的Datasheet PDF文件第15页浏览型号CDB5471的Datasheet PDF文件第16页浏览型号CDB5471的Datasheet PDF文件第18页浏览型号CDB5471的Datasheet PDF文件第19页浏览型号CDB5471的Datasheet PDF文件第20页浏览型号CDB5471的Datasheet PDF文件第21页  
CDB5471  
Figure 6. Data Collection Window (Time Domain)  
3.2.3.1. Last Value  
3.2.3.4. RMS  
The first column is labelled as “Last Value.” The  
value in this box represents the value of the very  
last instantaneous sample that was taken (for both  
channels) in the most recently-completed computa-  
tion cycle. If the user’s analog input waveforms are  
AC in nature, then this column of results will rarely  
have any meaning. But if the user applies a con-  
stant DC input signal to any of the analog input  
channels, then the Last Value column for that chan-  
nel should display an output code that is relatively  
constant from one conversion cycle to the next.  
The values in this column represent the computed  
RMS value over the most recently-completed com-  
putation cycle.  
3.2.4 Data Collection Window  
The Data Collection Window (Figs 6, 8, and 9) al-  
lows the user to collect samples sets of data from  
CS5471 and analyze them using time domain, FFT,  
and histogram plots. The Data Collection Window  
is accessible through the Menu option, or by press-  
ing F4.  
3.2.3.2. Mean  
3.2.4.1. Collect Button  
The values in this column represent the simple average  
of the sample values in the latest computation cycle.  
This button will collect data from the CS5471, to be  
analyzed in the plot area. See the section on Col-  
lecting Data Sets for more information.  
3.2.3.3. Std Dev.  
The values in this column represent the computed  
standard deviation over the set of values in the most  
recent computation cycle.  
DS480DB1  
17