欢迎访问ic37.com |
会员登录 免费注册
发布采购

CDB5460A 参数 Datasheet PDF下载

CDB5460A图片预览
型号: CDB5460A
PDF下载: 下载PDF文件 查看货源
内容描述: 评估板和软件 [Evaluation Board and Software]
分类和应用:
文件页数/大小: 28 页 / 1486 K
品牌: CIRRUS [ CIRRUS LOGIC ]
 浏览型号CDB5460A的Datasheet PDF文件第3页浏览型号CDB5460A的Datasheet PDF文件第4页浏览型号CDB5460A的Datasheet PDF文件第5页浏览型号CDB5460A的Datasheet PDF文件第6页浏览型号CDB5460A的Datasheet PDF文件第8页浏览型号CDB5460A的Datasheet PDF文件第9页浏览型号CDB5460A的Datasheet PDF文件第10页浏览型号CDB5460A的Datasheet PDF文件第11页  
CDB5460A  
Name  
Function Description  
Default Setting  
Default Jumpers  
Used to switch VIN+ on the CS5460A between J6  
and GND.  
O
O
O VIN+  
O GND  
J13  
VIN+ Set to BNC J6  
Used to switch VIN- on the CS5460A between J11  
and GND.  
O
O
O VIN-  
O GND  
J14  
J11  
VIN- Set to BNC J7  
Negative Analog  
Power Supply Set to  
0 V  
Used to switch VA-, A-, and GND. Refer toTable 2  
on page 6  
VA-  
A-  
O
O
O GND  
O GND  
Used to switch the VREFIN from external J26  
header, to the on board LT1019 reference, or to the  
on-chip reference VREFOUT. Refer to Table  
Table 1, “Reference Selection,” on page 5  
VREFIN Set to on-  
chip reference  
VREFOUT  
O
O
O
O LT1019  
O REF+  
O REFOUT  
J18  
J12  
Vu+ O O VDDD  
VD+ O O VDDD  
VD+ O O D+  
Used to switch VU+, VD+, and VA+ to VDDD  
and/or D+. Refer to Table 2, “Power Supply Con-  
nections,” on page 6  
Digital Power Supply  
Set to +5V  
VA+ O O D+  
J19  
J17  
Used to connect an external micro-controller.  
Connected to 80C51  
NC  
Used in conjunction with the self test modes to test  
the UART/RS-232 communication link between the  
microcontroller and a PC.  
RS-232 Set to Normal  
Mode  
O
O
O
O
Used to switch IIN+ on the CS5460A between J10  
and GND.  
O
O
O IIN+  
O GND  
J15  
J16  
J23  
IIN+ Set to BNC J9  
IIN- Set to BNC J8  
Used to switch IIN- on the CS5460A between J9  
and GND.  
O
O
O IIN-  
O GND  
Used to switch XIN on the CS5460A to HDR6 when XIN Set for on-board  
an external micro-controller is used.  
O
O
O GND  
O XIN  
4.096 MHz XTAL  
Used to connect PFMON pin on the CS5460A to  
monitor Power Supply VA+  
PFMON Set Monitor  
VA+  
O
O
O JP2  
JP2  
JP4  
Used to connect the RESET Button to the  
CS5460A  
RESET Set con-  
nected to CS5460A  
O JP4  
DIP switch to control 80C51 (See Table 4)  
S1-1 is used to enable auto-boot mode  
S1-2 is used to select crystal to 80C51  
S1-3 is used to select RS-232 test mode  
1
2
3
S1-1 Auto-Boot off  
S1-2 Set 20 MHz  
S1-3 Set Normal  
S1  
OPEN  
Allows LEDs D2 and D3 to indicate pulses on  
/EOUT and /EDIR. Pulse frequency must be less  
than ~6Hz to see light.  
J21  
J10  
Disable LEDs  
O
O J21  
O J10  
Used to disconnect XTAL1 input on microcontroller  
from off-board oscillator input.  
O
Use on-board crystal  
Table 3. Header, Jumper, and DIP Switch Descriptions  
7