欢迎访问ic37.com |
会员登录 免费注册
发布采购

CDB42L50 参数 Datasheet PDF下载

CDB42L50图片预览
型号: CDB42L50
PDF下载: 下载PDF文件 查看货源
内容描述: 低电压,立体声编解码器与耳机放大器 [Low Voltage, Stereo CODEC with headphone Amp]
分类和应用: 解码器编解码器放大器
文件页数/大小: 48 页 / 1371 K
品牌: CIRRUS [ CIRRUS LOGIC ]
 浏览型号CDB42L50的Datasheet PDF文件第5页浏览型号CDB42L50的Datasheet PDF文件第6页浏览型号CDB42L50的Datasheet PDF文件第7页浏览型号CDB42L50的Datasheet PDF文件第8页浏览型号CDB42L50的Datasheet PDF文件第10页浏览型号CDB42L50的Datasheet PDF文件第11页浏览型号CDB42L50的Datasheet PDF文件第12页浏览型号CDB42L50的Datasheet PDF文件第13页  
CS42L50  
ANALOG OUTPUT CHARACTERISTICS (Continued)  
Parameters  
Symbol  
Min  
Typ  
Max  
Units  
Analog Output  
Full Scale Line Output Voltage  
Line Output Quiescent Voltage  
Full Scale Headphone Output Voltage  
Headphone Output Quiescent Voltage  
Interchannel Gain Mismatch  
Gain Drift  
(Note 7) VFS_LINE TBD  
G x VA  
0.5 x VA_LINE  
0.55 x VA  
0.5 x VA_HP  
0.1  
TBD  
Vpp  
VDC  
Vpp  
VDC  
dB  
VQ_LINE  
VFS_HP  
VQ_HP  
-
-
TBD  
TBD  
-
-
-
-
-
-
100  
ppm/°C  
Maximum Line Output AC-Current  
VA=1.8 V ILINE  
VA=3.0 V  
-
0.1  
-
mA  
-
0.15  
-
mA  
Maximum Headphone Output  
AC-Current  
VA=VA_HP=1.8 V  
IHP  
-
-
31  
-
-
mA  
mA  
VA=VA_HP=3.0 V  
52  
Single Speed Mode  
Double Speed Mode  
Parameter  
Symbol Min  
Typ  
Max  
Min  
Typ  
Max Unit  
Combined Digital and On-chip Analog Filter Response (Note 8)  
Passband  
(Note 9)  
to -0.05 dB corner  
to -0.1 dB corner  
to -3 dB corner  
0
-
-
-
-
.4535  
-
-
-
-
-
-
Fs  
0
.4426 Fs  
0
.4998  
0
.4984 Fs  
Frequency Response 10 Hz to 20 kHz  
-.02  
-
+.08  
0
-
+0.11 dB  
(Note 10)  
StopBand  
StopBand Attenuation  
Group Delay  
.5465  
50  
-
-
-
-
-
-
.577  
55  
-
-
-
-
-
-
Fs  
dB  
s
(Note 11)  
tgd  
9/Fs  
4/Fs  
Passband Group Delay Deviation 0 - 40 kHz  
-
-
-
-
±1.39/Fs  
-
s
0 - 20 kHz  
-
±0.36/Fs  
-
-
±0.23/Fs  
-
s
De-emphasis Error  
(Relative to 1 kHz)  
Fs = 32 kHz  
Fs = 44.1 kHz  
Fs = 48 kHz  
-
-
-
-
-
-
+.2/-.1  
+.05/-.14  
+0/-.22  
dB  
dB  
dB  
(Note 12)  
Notes: 7. See Section 4.2.7 for details.  
8. Filter response is not tested but is guaranteed by design.  
9. Response is clock dependent and will scale with Fs. Note that the response plots (Figures 14 through 21)  
have been normalized to Fs and can be de-normalized by multiplying the X-axis scale by Fs.  
10. Referenced to a 1 kHz, full-scale sine wave.  
11. For Single Speed Mode, the measurement bandwidth is 0.5465 Fs to 3 Fs.  
For Double Speed Mode, the measurement bandwidth is 0.577 Fs to 1.4 Fs.  
12. De-emphasis is not available in Double Speed Mode.  
DS544PP1  