CS3720
Electrical Characteristics: 5.5V ² V
CC
² 17V; Ð40¡C ² T
J
² +150¡C; Ð40¡C ² T
C
² +105¡C; Ð40¡C ² T
A
² 105¡C; unless otherwise specified.
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
s
Output Stage
Quiescent Current
I
OUT
=0mA;
ENABLE1=DIRECTION= High
ENABLE2=Low
I
OUT
=2A
I
OUT
=500mA
I
OUT
=0mA
3.0
10
mA
Output Saturation Voltage
Output Leakage Current
Current Limit
s
Logic Control Functions
High Level Input Voltage
Low Level Input Voltage
High Level Input Current
Low Level Input Current
Turn on Delay
Guaranteed by design
Turn off Delay
Guaranteed by design
s
Fault Protection Functions
Overvoltage Shutdown
3.2
2.6
20
V
V
µA
A
2.0
0.8
10
-250
R
LOAD
=30�½; Coil=5mH;
C
LOAD
=15pF
R
LOAD
=30�½; Coil=5mH;
C
LOAD
=15pF
50
5
50
5
V
V
µA
µA
µs
µs
I
OUT
= 500mA
18.0
21.5
V
Package Lead Description
PACKAGE LEAD#
LEAD SYMBOL
FUNCTION
15 Lead
Power SIP
2
4
6
8
12
10
14
7 Lead
TO-220
1
2
3
4
5
6
7
7 Lead
D
2
PAK
1
2
3
4
5
6
7
ENABLE1
DIRECTION
COIL+
Gnd
V
SS
COIL-
ENABLE2
Enables output when held low and ENABLE 2 = High
Determines the direction of current flow through COIL+ and
COIL- as long as ENABLE1 = Low and ENABLE2 = High
Positive Output of H bridge to coil
Ground connection
Supply voltage for IC
Negative Output of H bridge to coil
Enables output when held high and ENABLE 1 = Low
Application Hints
Motor Direction Control
ENABLE1 ENABLE2
Low
Low
High
X
High
High
X
Low
DIRECTION
High
Low
X
X
COIL+
High
Low
OFF
OFF
COIL-
Low
High
OFF
OFF
Current flow through the two outputs COIL+ and COIL-
is controlled by the combined settings of ENABLE1,
ENABLE2 and DIRECTION (Table 1). The outputs will be
active only when ENABLE1 is low and ENABLE2 is high.
When DIRECTION is high, current flows out of COIL+
and into COIL-. When DIRECTION is low, current flows
out of COIL- and into COIL+. For any other combination
of ENABLE settings, the outputs are off.
2
Table 1. Logical Control Diagram