欢迎访问ic37.com |
会员登录 免费注册
发布采购

SMCW6020 参数 Datasheet PDF下载

SMCW6020图片预览
型号: SMCW6020
PDF下载: 下载PDF文件 查看货源
内容描述: 固态继电器用于电机控制 [Solid State Relays For Motor Control]
分类和应用: 继电器固态继电器电机
文件页数/大小: 16 页 / 1239 K
品牌: CELDUC [ celduc-relais ]
 浏览型号SMCW6020的Datasheet PDF文件第6页浏览型号SMCW6020的Datasheet PDF文件第7页浏览型号SMCW6020的Datasheet PDF文件第8页浏览型号SMCW6020的Datasheet PDF文件第9页浏览型号SMCW6020的Datasheet PDF文件第11页浏览型号SMCW6020的Datasheet PDF文件第12页浏览型号SMCW6020的Datasheet PDF文件第13页浏览型号SMCW6020的Datasheet PDF文件第14页  
S/MOT/SMCW6020/B/05/07/99  
1W240040  
®
Solid Sta t e Rela ys  
F or Motor Con tr ol  
celduc  
r
e
l
a
i
s
P a ge 10/16  
STANDARDS  
IMMUNITY LE VE L WITHIN E LE CTROMAGNE TIC COMP ATIBILITY (E.M.C.)  
VALUE S  
CHARACTER ISTICS  
LABELS  
R EMAR KS  
No st a t e  
ch a n gin g or  
d est r u ct ion  
No st a t e  
ch a n gin g or  
d est r u ct ion  
No st a t e  
ch a n gin g or  
d est r u ct ion  
No st a t e  
(Given a t 20°C a m bien t u n less oth er w ise sp ecified )  
E N  
61000-4-2  
8kV in the air  
4kV contact  
E lectr ost a t ic d isch a r ges  
R a d ia t ed Elect r om a gn et ic F ield s  
F a st Tr a n sien t Bu r st s  
E N  
61000-4-3  
10V/m  
E N  
61000-4-4  
2kV direct coupling on the power side  
2kV clamped coupling on the input side  
E N  
61000-4-5  
1kV direct coupling differential mode (Input and output sides)  
2kV direct coupling common mode (Input and output sides)  
E lectr ic ch ock s  
Volt a ge Dr op  
ch a n gin g or  
d est r u ct ion  
E N  
61000-4-11  
EMISSION LEVEL WITHIN ELECTROMAGNETIC COMP ATIBILITY (E.M.C.)  
VALUE S  
CHARACTER ISTICS  
LABELS  
E N55011  
E N55011  
R EMAR KS  
(Given a t 20°C a m bien t u n less oth er w ise sp ecified )  
In com p lia n ce w it h t h e st a n d a r d s  
for in d u str ia l field  
In com p lia n ce w it h t h e st a n d a r d s  
for d om estic field w it h a n ext er n a l byp a ss con ta ctor  
<30d bµV for t h e fr equ en cy r a n ge 30->230MHz  
<37d bµV for t h e fr equ en cy r a n ge 230->1000MHz  
Con d u ct ed Distu r ba n ces  
R a d ia t ed Dist u r ba n ces  
The conducted or radiated disturbances generated by solid  
state relays depend on the wiring and load configuration.  
The test method recommended by the European standards  
and concerning electromagnetic compatibility leading to results  
far from reality, we decided to advise our customer in order to  
adapt their filtering scheme to their application.  
The European standard EN60947-4-2 requires the  
measurement to be done at full on state (end of the softstarting  
period). Therefore, our products are below the industrial field  
required levels on inductive load like the induction motor and  
n o a d d it ion a l filt er is needed.  
Rem a r k s Con cer n in g F ilt er in g  
The starting period that may last several minutes  
generates enough interference to disturb sensitive devices  
located near the softstarter. If any, please contact us so that we  
can help you to choose the right filter.  
LOW VOLTAGE DIR ECTIVE  
VALUE S  
CHARACTER ISTICS  
LABELS  
IP  
R EMAR KS  
(Given a t 20°C a m bien t u n less oth er w ise sp ecified )  
EN60947-4-2  
2L0  
St a n d a r d  
P r ot ect ion Level  
According to V.D.E. 160 part 100 : Back hand and finger safety  
P r ot ect ion F or Dir ect Tou ch  
AP P R OVALS  
VALUE S  
CHARACTER ISTICS  
LABELS  
R EMAR KS  
(Given a t 20°C a m bien t u n less oth er w ise sp ecified )  
E N  
60947-4-2  
UL508  
CE Ma r k in g  
c UL US  
Yes  
Pending  
Pending  
Office  
en vir on m en t  
VDE 0805  
E N60950  
 复制成功!