 浏览型号CAT1021WI-42TE13的Datasheet PDF文件第5页浏览型号CAT1021WI-42TE13的Datasheet PDF文件第6页浏览型号CAT1021WI-42TE13的Datasheet PDF文件第7页浏览型号CAT1021WI-42TE13的Datasheet PDF文件第8页浏览型号CAT1021WI-42TE13的Datasheet PDF文件第10页浏览型号CAT1021WI-42TE13的Datasheet PDF文件第11页浏览型号CAT1021WI-42TE13的Datasheet PDF文件第12页浏览型号CAT1021WI-42TE13的Datasheet PDF文件第13页  
CAT1021, CAT1022, CAT1023  
SDA when SCL is HIGH. The CAT1021/22/23 monitor  
the SDA and SCL lines and will not respond until this  
condition is met.  
EMBEDDED EEPROM OPERATION  
The CAT1021/22/23 feature a 2kbit embedded serial  
EEPROM that supports the I2C Bus data transmission  
protocol.ThisInter-IntegratedCircuitBusprotocoldefines  
any device that sends data to the bus to be a transmitter  
and any device receiving data to be a receiver. The  
transfer is controlled by the Master device which  
generates the serial clock and all START and STOP  
conditions for bus access. Both the Master device and  
Slavedevicecanoperateaseithertransmitterorreceiver,  
but the Master device controls which mode is activated.  
STOP Condition  
A LOW to HIGH transition of SDA when SCL is HIGH  
determinestheSTOPcondition.Alloperationsmustend  
with a STOP condition.  
DEVICE ADDRESSING  
The Master begins a transmission by sending a START  
condition.TheMastersendstheaddressoftheparticular  
slave device it is requesting. The four most significant  
bitsofthe8-bitslaveaddressareprogrammableinmetal  
and the default is 1010.  
I2C Bus Protocol  
The features of the I2C bus protocol are defined as  
follows:  
(1) Data transfer may be initiated only when the bus is  
not busy.  
The last bit of the slave address specifies whether a  
ReadorWriteoperationistobeperformed.Whenthisbit  
is set to 1, a Read operation is selected, and when set  
to 0, a Write operation is selected.  
(2) During a data transfer, the data line must remain  
stable whenever the clock line is high. Any changes in  
thedatalinewhiletheclocklineishighwillbeinterpreted  
as a START or STOP condition.  
After the Master sends a START condition and the slave  
address byte, the CAT1021/22/23 monitors the bus and  
responds with an acknowledge (on the SDA line) when  
its address matches the transmitted slave address. The  
CAT1021/22/23 then perform a Read or Write operation  
depending on the R/W bit.  
START Condition  
The START Condition precedes all commands to the  
device, and is defined as a HIGH to LOW transition of  
Figure 3. Bus Timing  
t
t
t
F
HIGH  
R
t
t
LOW  
LOW  
SCL  
t
t
HD:DAT  
SU:STA  
t
t
t
t
HD:STA  
SU:DAT  
SU:STO  
SDA IN  
BUF  
t
t
DH  
AA  
SDA OUT  
Figure 4. Write Cycle Timing  
SCL  
SDA  
8TH BIT  
BYTE n  
ACK  
t
WR  
STOP  
CONDITION  
START  
CONDITION  
ADDRESS  
Doc No. 3009, Rev. K  
9