23
C-Series Circuit Breaker - Flat Rocker UL489 Listed – Ordering Scheme
C 1 2 B 0 14 450 1 2 A K G
8
9
10
Mounting/
Barriers
11
12
1
2
3
4
5
6
7
Terminal
Actuator
Color
Max. App. Agency
Rating
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
Approval
5
7 CURRENT RATING (AMPERES)
1 SERIES
C
CODE AMPERES
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
650 50.000
660 60.000
670 70.000
680 80.000
685 85.000
690 90.000
695 95.000
810 100.00
1
2 ACTUATOR
Two Color Visi-Rocker
Push-To-Reset, Visi-Rocker
1
2
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
5
6
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
Single color
Push-To-Reset , Single color
3
4
Vertical legend
Horizontal legend
7
8
Vertical legend
Horizontal legend
8 TERMINAL
6
8
8,9
8
1
2
3
4
5
Stud 10-32
6
Stud M6
7
8
7
7
Screw 10-32
Stud 1/4-20
Stud M5 x 0.8
9
7/16” Clip Terminal
Plug-In Stud
A
C
7,9
5/16” Clip Terminal
Screw M5 x 0.8
10
9 ACTUATOR COLOR & LEGEND
2
3 POLES
One
Actuator or
1
2
Two
3
Three
Visi-Color
Marking:
Marking Color:
Single Color
Rocker/Handle
Black
11,12
Color:
White
Black
Red
ON-OFF Dual
Visi-Rocker
White
n/a
4 CIRCUIT
Series Trip (current)
B
D
G
J
1
2
3
4
5
6
7
8
B
White
White
Red
Green
Blue
White
Green
Blue
3
5 AUXILIARY / ALARM SWITCH
L
White
Yellow
Gray
Orange
N
Q
S
Black
Yellow
Gray
0
2
3
4
without Aux Switch
Black
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.139 Solder Lug
S.P.D.T., 0.110 Q.C. Term.
(Gold Contacts)
6
8
9
S.P.S.T., 0.139 Solder Lug
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
Black
Orange
10 MOUNTING / BARRIERS
15
STANDARD ROCKER BEZEL
Threaded Insert, 2 per pole
6-32 X 0.195 inches
BARRIERS
6 FREQUENCY & DELAY
11 DC Ultra Short
12 DC Short
14 DC Medium
16 DC Long
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
4
4
4
4
4
4
A
C
yes
yes
42 50/60Hz Short, High-inrush
ISO M3 x 5mm
44 50/60Hz Medium, High-inrush
14
RECESSED OFF ROCKER
46 50/60Hz Long, High-inrush
Threaded Insert, 2 per pole
6-32 x 0.195 inches
ISO M3 x 5mm
52 DC Short, High-inrush
E
F
yes
yes
54 DC Medium, High-inrush
56 DC Long, High-inrush
13
PUSH-TO-RESET BEZEL
Threaded Insert, 2 per pole
6-32 x 0.195 inches
ISO M3 x 5mm
B
D
yes
yes
Notes:
1
2
Push-to-reset actuators have OFF portion of rocker shrouded.
Multi-pole breakers have all breakers identical except when specifying Auxiliary
switch and/or mixed poles, and have one rocker per breaker.
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme
right pole.
11 MAXIMUM APPLICATION RATING
3
B
C
D
F
K
M
125 DC
120/240 AC
240 AC
277 AC
120 AC
80 DC
16
4
5
6
7
8
9
Available up to 50 amps maximum.
Current ratings 71 - 100 with VDE approvals are available up to two poles maximum.
Terminal Code 1 available to 60 amps maximum.
Terminal Codes 2, 4, 5 & C available to 50 amps maximum.
Terminal Codes 3, 6, 9 & A available to 100 amps maximum.
Terminal Codes 9 & C are not VDE approved.
10 Color shown is visi and legend with remainder of rocker black
11 Dual = ON-OFF/I-O legend on actuator.
12 TUV approval requires Dual (I-O, ON-OFF) markings on rocker.
13 Legend on push-to-reset bezel/shroud is white when single color rocker is ordered.
Legend on push-to-reset bezel/shroud matches visi-color of rocker with actuator
codes 5 & 6.
12
12 AGENCY APPROVAL
A
G
J
without approvals
UL 489 Listed & CSA Certified
UL489 Listed, CSA Certified & TUV Certified
14 Recessed “OFF-SIDE” available with actuator codes 1, 2, 3, & 4. Legends on rocker
are available in ink stamping only.
15 Barriers supplied on multi-pole units only.
16 2 & 3 pole circuit breakers required for 120/240 AC rating.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com