 浏览型号BB4-B0-24-630-411-C的Datasheet PDF文件第1页浏览型号BB4-B0-24-630-411-C的Datasheet PDF文件第3页浏览型号BB4-B0-24-630-411-C的Datasheet PDF文件第4页浏览型号BB4-B0-24-630-411-C的Datasheet PDF文件第5页浏览型号BB4-B0-24-630-411-C的Datasheet PDF文件第6页浏览型号BB4-B0-24-630-411-C的Datasheet PDF文件第7页浏览型号BB4-B0-24-630-411-C的Datasheet PDF文件第8页浏览型号BB4-B0-24-630-411-C的Datasheet PDF文件第9页  
|
B-Series Circuit Breaker – General Specifications  
2
Electrical  
Maximum Voltage  
Current Ratings  
Mechanical  
277VAC 50/60 Hz, 80VDC  
Standard current coils: 0.100,  
0.250, 0.500, 0.750, 1.00, 2.50,  
5.00, 7.50, 10.0, 15.0, 20.0, 25.0,  
30.0, 35.0, 40.0 and 50.0 amps.  
Other ratings available, see  
ordering scheme.  
Endurance  
10,000 ON-OFF operations @ 6 per  
minute; with rated Current and  
Voltage.  
All B-Series Circuit Breakers will  
trip on overload, even when Handle  
is forcibly held in the ON position.  
The operating Handle moves  
positively to the OFF position when  
an overload causes the breaker to  
trip.  
Trip Free  
Trip Indication  
Standard Voltage Coils DC - 6V, 12V; AC - 120V, other  
ratings available, see ordering  
scheme.  
Auxiliary Switch Rating SPDT; 10.1 AMPS - 250VAC,1.0A  
65 VDC or 0.5A 80 VDC, 0.1 Amps  
- 125VAC (with gold contacts).  
Physical  
Number of Poles  
1 - 6 poles at 30 Amps or less. 1  
and 2 poles at 31 Amps thru 50  
Amps.  
VDE-1.0 Amp - 125VAC.  
Minimum of 100 Megohms at 500  
VDC.  
Insulation Resistance  
Dielectric Strength  
Internal Circuit Config. Series, (with or without auxiliary  
switch), Shunt and Relay with  
UL, CSA-1500 V 50/60 Hz for one  
minute between all electrically  
isolated terminals. B-Series circuit  
breakers comply with the 8mm  
spacing and 3750V 50/60 Hz  
dielectric requirements from  
hazardous voltage to operator  
accessible surfaces, between  
adjacent poles and from main  
circuits to auxiliary circuits per  
Publications EN 60950 and VDE  
0805.  
current or voltage trip coils, Dual  
Coil, Switch Only (with or without  
auxiliary switch).  
Approximately 65 grams/pole.  
(Approximately 2.32 ounces/pole.)  
Housing- Black; Actuator - See  
Ordering Scheme.  
Weight  
Standard Colors  
Environmental  
Designed and tested in accordance with requirements of  
specification MIL-PRF-55629 & MIL-STD-202 as follows:  
Resistance, Impedance Values from Line to Load Terminal  
- based on Series Trip Circuit  
Breaker.  
RESISTANCE PER POLE VALUES  
from Line to Load Terminals  
(Values Based on Series Trip Circuit Breaker)  
Shock  
Withstands 100 Gs, 6ms, sawtooth  
while carrying rated current per  
Method 213, Test Condition “I”.  
Instantaneous and ultra-short  
curves tested @ 90% of rated  
current.  
Withstands 0.060” excursion from  
10-55 Hz, and 10 Gs 55-500 Hz,  
at rated current per Method 204C,  
Test Condition A. Instantaneous  
and ultrashort curves tested at 90%  
of rated current.  
CURRENT  
(AMPS)  
TOLERANCE  
(%)  
0.10 - 5.0  
5.1 - 20.0  
20.1 - 50.0  
15  
25  
35  
Vibration  
Moisture Resistance  
Method 106D, i.e., ten 24-hour  
cycles @ + 25°C to +65°C, 80-98%  
RH.  
Salt Spray  
Method 101, Condition A (90-95%  
RH @ 5% NaCl Solution, 96 hrs).  
Method 107D, Condition A (Five  
cycles @ -55°C to +25°C to +85°C  
to +25°C).  
Pulse Tolerance Curves  
Thermal Shock  
Operating Temperature -40° C to +85° C  
*Manufacturer reserves the right to change product specification without prior notice.  