Mechanical
TOP MOUNTED
FAN
1
TB1
PLUS
6.94
3.34
NO. 1 +V
OUTPUTS
NO. 1 -V
FAN OPTION
1
2
3
AIR FLOW
MINUS
OUTPUT OUTPUT
4
3
ADJ.
ADJ.
OUTPUT
5
ADJ.
1
4.85 3.60
3.90
0.62
0.55
0.25
1
TB2
6-32 MOUNTING LOCATED ON BOTTOM (4x)
8.50
9.00
1.99
3.00
END MOUNTED
FAN
0.250
8.50
2.15
0.550
J10
TB2
3.900
AIR FLOW
4.850
J9
3
2
1
1.00
9.00
6-32 THD
4 PLC'S
OUTPUT NO. 1
RETURN
10-32 STUD
OUTPUT NO. 1
10-32 STUD
NOTES:
All measurements are in inches
COOLING:
The DNX350 is designed to operate with 30 CM airflow.
SHOCK AND VIBRATION:
The DNX350 meets the requirements of MIL STD-810D.
WEIGHT:
Approximately 3 lbs.
1
Terminal Block 1
POS
1
2
3
FUNCTION
DC +
DC -
Ground
Terminal Block 2
POS
1
2
3
4
5
6
FUNCTION
-V2
+V2
-V3
+V3
-V4
+V4
PIN
1
2
3
4
5
6
7
8
9
J9 Connector
Molex No. 22-28-1090
FUNCTION
+ Sense
- Sense
N/C
N/C
Start Up Sync.
N/C
Remote Inhibit
Current Share
Control Signal Rtn
POS
1
2
3
J10 Connector*
AMP 1-480701-1
FUNCTION
DC+
DC-
GROUND
*Used with end-mounted fan cover,
option “V”
Page 4