Mechanical
TOP VIEW
0.25
0.55
8.50
1.95
0.040
COVER
1
TB2
3.90
4.85
1
J9
1
OUTPUT NO. 1
5V RETURN
TB1
9.00
5V
6-32 THD 4 PLC’S
Maximum depth of mounting
scres is 0.156 inches
NOTES:
All measurements are in inches
FAN MOUNTED ON COVER ADDS 1.30”.
COOLING:
The DNX301 is designed to operate with 30 CM airflow.
SHOCK AND VIBRATION:
The DNX301 meets the requirements of MIL STD-810D.
WEIGHT:
Approximately 3 lbs.
Terminal Block 1
POS
1
2
3
FUNCTION
DC +
DC -
Ground
Terminal Block 2
POS
1
2
3
4
5
6
FUNCTION
-V2
+V2
-V3
+V3
-V4
+V4
J9 Connector
Molex No. 22-28-1090
PIN
1
2
3
4
5
6
7
8
9
FUNCTION
+ Sense
- Sense
N/C
N/C
Start Up Sync.
N/C
Remote Inhibit
Current Share
Control Signal Rtn
Page 4