CALIFORNIA MICRO DEVICES
CMPWR300
ABSOLUTE MAXIMUM RATINGS
Parameter
Rating
2000
Unit
V
ESD Protection (HBM)
VCC VSBY Input Voltage
VAUX Input Voltage
+6.0, Gnd -0.5
+4.0, Gnd -0.5
-40 to +150
0 to +70
V
V
Storage Temperature Range
Operating Ambient
oC
W
Operating Junction
0 to +125
1.0
Note 1
Power Dissipation:
OPERATING CONDITIONS
Parameter
VCC, VSBY
Range
Unit
V
5.0 ± 0.25
3.3 ± 0.3
0 to +70
0 to 500
VAUX
V
oC
Temperature (Ambient)
Load Current
C EXT
mA
mF
10 ± 10%
E LE C TR IC A L O P E R A TIN G C H A R A C TE R IS TIC S
( o ve r o p e r a t in g c o n d it io n s u n le s s s p e c if ie d o t h e r w is e )
Sym bol Param eter
Conditions
MIN
3.135
500
TYP
3.30
800
20
MAX
UNIT
V
VOUT
IOUT
Regulator Output Voltage
500mA > ILOAD> 0mA
3.465
Regulator Output Current
Load Regulation
mA
mV
mV
VRLOAD
VRLINE
VCCSEL
VCCDES
VSBYSEL
VSBYDES
VHYST
RSW
VCC= 5V, ILOAD = 50mA to 500mA
VCC = 4.5V to 5.5V, ILOAD = 5mA
Line Regulation
2
VCCSelect Voltage
4.50
4.20
4.50
4.20
0.30
0.12
2000
4.60
4.60
VCCDeselect Voltage
VSBYSelect Voltage
VSBY> VSBYDES or VAUXpresent
VCC< VCCDES
3.90
3.90
V
VSBYDeselect Voltage
Hysteresis Voltage: Note 2
Auxiliary Switch Resistance
Short Circuit Current
VCC Pin Reverse Leakage
VSBY Pin Reverse Leakage
VAUX Pin Reverse Leakage
VCC Supply Current
VAUXpresent
Applies to VCCand VSBYselection
VCC/SBYare deselected
0.2
Ω
mA
IS/C
VCC/SBY= 5V, VOUT= 0V
One supply input taken to ground
while the others remain at normal
voltage
IRCC
IRSBY
5
50
µA
IRAUX
ICC
VCC > VCCSEL, ILOAD= 0mA
VCCDES > VCC > VOUT
1.0
0.15
0.01
1.0
3.0
0.25
0.02
3.0
(when VCC is not present)
mA
VOUT> VCC
ISBY
VSBY Supply Current
VSBY> VSBYSEL, ILOAD= 0mA
VSBYDES > VSBY> VOUT
(when VCC is not present)
0.15
0.01
0.05
0.2
0.25
0.02
0.1
mA
mA
V
OUT> VSBY
VCCor VSBY> VOUT
CCand VSBY< VOUT
IAUX
IGND
VAUX Supply Current
Ground Current: Note 3
V
0.4
Both VCCand VSBYare delection
VCC/SBY= 5V, ILOAD= 0mA
0.15
1.0
0.30
3.0
mA
VCC/SBY= 5V, ILOAD= 500mA
1.2
3.5
Note 1: The thermal resistance from junction to ambient (θJA) must be less than 55° C/W. This is typically achieved with 2 square inches of
copper printed circuit board area connected to the GND pins for heat spreading, or equivalent.
Note 2: The hysteresis defines the maximum level of acceptable disturbance on VCC during switching.
Note 3: Ground current consists of controller current and regulator current if enabled.
©2000 California Micro Devices Corp. All rights reserved.
12/5/2000
215 Topaz Street, Milpitas, California 95035
Tel: (408) 263-3214
Fax: (408) 263-7846
www.calmicro.com
2