ABSOLUTE MAXIMUM RATINGS  
Parameter  
Rating  
2000  
Unit  
V
ESD Protection (HBM)  
VCC VSBY Input Voltage  
VAUX Input Voltage  
+6.0, Gnd -0.5  
+4.0, Gnd -0.5  
-40 to +150  
0 to +70  
V
V
Storage Temperature Range  
Operating Ambient  
oC  
W
Operating Junction  
0 to +125  
1.0  
Note 1  
Power Dissipation:  
OPERATING CONDITIONS  
Parameter  
VCC, VSBY  
Range  
Unit  
V
5.0 ± 0.25  
3.3 ± 0.3  
0 to +70  
0 to 500  
VAUX  
V
oC  
Temperature (Ambient)  
Load Current  
C EXT  
mA  
mF  
10 ± 10%  
E LE C TR IC A L O P E R A TIN G C H A R A C TE R IS TIC S  
( o ve r o p e r a t in g c o n d it io n s u n le s s s p e c if ie d o t h e r w is e )  
Sym bol Param eter  
Conditions  
MIN  
3.135  
500  
TYP  
3.30  
800  
20  
MAX  
UNIT  
V
VOUT  
IOUT  
Regulator Output Voltage  
500mA > ILOAD> 0mA  
3.465  
Regulator Output Current  
Load Regulation  
mA  
mV  
mV  
VRLOAD  
VRLINE  
VCCSEL  
VCCDES  
VSBYSEL  
VSBYDES  
VHYST  
RSW  
VCC= 5V, ILOAD = 50mA to 500mA  
VCC = 4.5V to 5.5V, ILOAD = 5mA  
Line Regulation  
2
VCCSelect Voltage  
4.50  
4.20  
4.50  
4.20  
0.30  
0.12  
2000  
4.60  
4.60  
VCCDeselect Voltage  
VSBYSelect Voltage  
VSBY> VSBYDES or VAUXpresent  
VCC< VCCDES  
3.90  
3.90  
V
VSBYDeselect Voltage  
Hysteresis Voltage: Note 2  
Auxiliary Switch Resistance  
Short Circuit Current  
VCC Pin Reverse Leakage  
VSBY Pin Reverse Leakage  
VAUX Pin Reverse Leakage  
VCC Supply Current  
VAUXpresent  
Applies to VCCand VSBYselection  
VCC/SBYare deselected  
0.2  
mA  
IS/C  
VCC/SBY= 5V, VOUT= 0V  
One supply input taken to ground  
while the others remain at normal  
voltage  
IRCC  
IRSBY  
5
50  
µA  
IRAUX  
ICC  
VCC > VCCSEL, ILOAD= 0mA  
VCCDES > VCC > VOUT  
1.0  
0.15  
0.01  
1.0  
3.0  
0.25  
0.02  
3.0  
(when VCC is not present)  
mA  
VOUT> VCC  
ISBY  
VSBY Supply Current  
VSBY> VSBYSEL, ILOAD= 0mA  
VSBYDES > VSBY> VOUT  
(when VCC is not present)  
0.15  
0.01  
0.05  
0.2  
0.25  
0.02  
0.1  
mA  
mA  
V
OUT> VSBY  
VCCor VSBY> VOUT  
CCand VSBY< VOUT  
IAUX  
IGND  
VAUX Supply Current  
Ground Current: Note 3  
V
0.4  
Both VCCand VSBYare delection  
VCC/SBY= 5V, ILOAD= 0mA  
0.15  
1.0  
0.30  
3.0  
mA  
VCC/SBY= 5V, ILOAD= 500mA  
1.2  
3.5  
Note 1: The thermal resistance from junction to ambient (θJA) must be less than 55° C/W. This is typically achieved with 2 square inches of  
copper printed circuit board area connected to the GND pins for heat spreading, or equivalent.  
Note 2: The hysteresis defines the maximum level of acceptable disturbance on VCC during switching.  
Note 3: Ground current consists of controller current and regulator current if enabled.  
©2000 California Micro Devices Corp. All rights reserved.  
12/5/2000  
215 Topaz Street, Milpitas, California 95035  
Tel: (408) 263-3214  
Fax: (408) 263-7846  
www.calmicro.com  