欢迎访问ic37.com |
会员登录 免费注册
发布采购

TMC2330AKEC 参数 Datasheet PDF下载

TMC2330AKEC图片预览
型号: TMC2330AKEC
PDF下载: 下载PDF文件 查看货源
内容描述: 协调变压器16 x 16位, 40 MOPS [Coordinate Transformer 16 x 16 Bit, 40 MOPS]
分类和应用: 变压器外围集成电路时钟
文件页数/大小: 18 页 / 269 K
品牌: CADEKA [ CADEKA MICROCIRCUITS LLC. ]
 浏览型号TMC2330AKEC的Datasheet PDF文件第7页浏览型号TMC2330AKEC的Datasheet PDF文件第8页浏览型号TMC2330AKEC的Datasheet PDF文件第9页浏览型号TMC2330AKEC的Datasheet PDF文件第10页浏览型号TMC2330AKEC的Datasheet PDF文件第12页浏览型号TMC2330AKEC的Datasheet PDF文件第13页浏览型号TMC2330AKEC的Datasheet PDF文件第14页浏览型号TMC2330AKEC的Datasheet PDF文件第15页  
TMC2330A  
PRODUCT SPECIFICATION  
Table 3a. X-Dimensional Marginal Overows  
Performing Scan Conversion with  
the TMC2330A  
TC  
0
YPIN  
OV  
1
RXOUT  
0000 = +0  
CORRECT X  
+32768  
0000 = 0  
8000 = π  
0000 = 0  
8000 = π  
Medical Imaging Systems such as Ultrasound, MRI, and  
PET, and phased array Radar and Sonar systems generate  
radial-format coordinates (range or distance, and bearing)  
which must be converted into raster-scan format for further  
processing and display. Utilizing the TMC2302A Image  
Resampling Sequencer, a minimum chipcount Scan Con-  
verter can be implemented which utilizes the trigonometric  
translation performed by the TMC2330A to backwards-map  
from a Cartesian coordinate set into the Polar source image  
buffer address space.  
0
1
8000 = -0  
-32768  
1
1
8000 = -32768  
8000 = -32768  
+32768  
1
0
-32768  
In all cases, RTP=0 (Polar-To-Rectangular mode) and  
XRIN=8000 (incoming radius=32768).  
Table 3b. Maximal Overow (Radius In=65535)  
TC  
0
YPIN  
OV  
1
RXOUT  
7FFF = +32767  
FFFF = -32767  
FFFF = -1  
CORRECT X  
+65535  
As shown in Figure 2, the TMC2330A transforms the Carte-  
sian source image addresses from the TMC2302A directly to  
vector distance and angle coordinates, while the TMC2302A  
writes the resulting resampled pixel values into the target  
memory in raster fashion. Note that the ability to perform  
this spatial transformation in either direction gives the user  
the freedom to process images in either coordinate space,  
with little restriction. Image manipulation such as zooms or  
tilts can easily be included in the transformation by program-  
ming the desired image manipulation into the TMC2302A’s  
transformation parameter registers.  
0000 = 0  
8000 = π  
0000 = 0  
8000 = π  
0
1
-65535  
1
1
+65535  
1
1
0001 = +1  
-65535  
In all cases, RTP=0 (Polar-To-Rectangular mode) and  
XRIN=7FFF (incoming radius=65535, which will always  
overflow).  
Numeric Underow  
In RTP=1 (Rectangular-To-Polar) mode, if XRIN=YPIN=0, the  
angle is undefined. Under these conditions, the TMC2330A  
will output the expected radius of 0 (RXOUT= 0000) and an  
angle of 1.744 radians (PYOUT=4707). This angle is an artifact  
of the CORDIC algorithm and is not flagged as an error,  
since the angle of any 0 length vector is arbitrary.  
X = R (Cos θ)  
π/2  
Y = R (Sin θ)  
65535  
and  
2
2
R =  
X
+ Y  
-1  
θ = Tan (Y/X)  
If R 32767, overflow will not occur (Region A).  
If R > 32767, overflow will not occur (Region B) if |X| 32767 and |Y| 32767.  
If R > 32767, overflow will occur (Region C) if |X| 32768 or |Y| 32768.  
C
32767  
B
A
R
θ
Y
X
32767  
65535  
Figure 1. First Quadrant Coordinate Relationships  
REV. 1.1.8 10/31/00  
11  
 复制成功!