欢迎访问ic37.com |
会员登录 免费注册
发布采购

TMC2330AG1C 参数 Datasheet PDF下载

TMC2330AG1C图片预览
型号: TMC2330AG1C
PDF下载: 下载PDF文件 查看货源
内容描述: 协调变压器16 x 16位, 40 MOPS [Coordinate Transformer 16 x 16 Bit, 40 MOPS]
分类和应用: 变压器
文件页数/大小: 18 页 / 269 K
品牌: CADEKA [ CADEKA MICROCIRCUITS LLC. ]
 浏览型号TMC2330AG1C的Datasheet PDF文件第3页浏览型号TMC2330AG1C的Datasheet PDF文件第4页浏览型号TMC2330AG1C的Datasheet PDF文件第5页浏览型号TMC2330AG1C的Datasheet PDF文件第6页浏览型号TMC2330AG1C的Datasheet PDF文件第8页浏览型号TMC2330AG1C的Datasheet PDF文件第9页浏览型号TMC2330AG1C的Datasheet PDF文件第10页浏览型号TMC2330AG1C的Datasheet PDF文件第11页  
TMC2330A
PRODUCT SPECIFICATION
Pin Descriptions
Pin Name
RTP
(continued)
Pin Number
MQFP
11
CPGA/PPGA/
MPGA
E1
Description
This registered input selects the current transformation
mode of the device. When RTP is HIGH, the TMC2330A
executes a Rectangular-To-Polar conversion. When RTP
is LOW, a Polar-To-Rectangular conversion will be
performed.
The input and output ports are then configured to handle
data in the appropriate coordinate system.
This is a static input. See the Timing Diagram.
In applications utilizing the TMC2330A to perform
waveform synthesis and modulation in the
Polar-To-Rectangular mode (RTP=LOW), the user
determines the internal phase Accumulator structure
implemented on the next clock by setting the accumulator
control word ACC
1,0
, as shown below:
ACC
1,0
00
01
10
11
Configuration
No accumulation performed (normal operation)
PM accumulator path enabled
FM accumulator path enabled
(Nonsensical) logical OR of PM and FM
ACC
1,0
19, 18
H2, H1
where 0 = L0W, 1 = HIGH. See the Functional Block
Diagram.
The accumulator will roll over correctly when full-scale is
exceeded, allowing the user to perform continuous phase
accumulation through 2π radians or 360 degrees.
Note that the accumulators will also function when
RTP=HIGH (Rectangular-To-Polar), which is useful when
performing backward mapping from Cartesian to polar
coordinates. However, most applications will require that
ACC
1,0
be set to 00 to avoid accumulating the Cartesian Y
input data.
TCXY
14
F1
The format select control sets the numeric format of the
Rectangular data, whether input (RTP=HIGH) or output
(RTP=LOW). This control indicates two’s complement
format when TCXY=HIGH and sign-and-magnitude when
LOW. This is a static input. See the Timing Diagram.
When RTP=LOW (Polar-To-Rectangular), the Overflow
Flag will go HIGH on the clock that the magnitude of either
of the current Cartesian coordinate outputs exceeds the
maximum range. It will return LOW on the clock that the
Cartesian out-put value(s) return to full-scale or less. See
the Applications Discussion section. Overflow is not
possible in Rectangular-To-Polar mode (RTP = HIGH).
Data in the output registers are available at the outputs of
the device when the respective asynchronous Output
Enables are LOW. When OERX or OEPY is HIGH, the
respective output port(s) is in the high impedance state.
OVF
105
B7
OERX,
OEPY
81, 9
E13, D1
REV. 1.1.8 10/31/00
7