Data Sheet
Absolute Maximum Ratings
The safety of the device is not guaranteed when it is operated above the “Absolute Maximum Ratings”. The device
should not be operated at these “absolute” limits. Adhere to the “Recommended Operating Conditions” for proper de-
vice function. The information contained in the Electrical Characteristics tables and Typical Performance plots reflect the
operating conditions noted on the tables and plots.
Comlinear CLC2600, CLC3600, CLC4600
Dual, Triple, and Quad 300MHz Amplifiers
Parameter
Supply Voltage
Input Voltage Range
Min
0
-V
s
-0.5V
Max
±7 or 14
+V
s
+0.5V
Unit
V
V
Reliability Information
Parameter
Junction Temperature
Storage Temperature Range
Lead Temperature (Soldering, 10s)
Package Thermal Resistance
8-Lead SOIC
14-Lead SOIC
Notes:
Package thermal resistance (q
JA
), JDEC standard, multi-layer test boards, still air.
Min
-65
Typ
Max
150
150
260
Unit
°C
°C
°C
°C/W
°C/W
100
88
ESD Protection
Product
Human Body Model (HBM)
Charged Device Model (CDM)
SOIC-8
2.5kV
2kV
SOIC-14
2.5kV
2kV
Recommended Operating Conditions
Parameter
Operating Temperature Range
Supply Voltage Range
Min
-40
±4
Typ
Max
+85
±6
Unit
°C
V
Rev 1A
©2004-2008 CADEKA Microcircuits LLC
www.cadeka.com
3