Data Sheet
Absolute Maximum Ratings
The safety of the device is not guaranteed when it is operated above the “Absolute Maximum Ratings”. The device
should not be operated at these “absolute” limits. Adhere to the “Recommended Operating Conditions” for proper
device function. The information contained in the Electrical Characteristics tables and Typical Performance plots reflect
the operating conditions noted on the tables and plots.
Comlinear CLC2005
Dual, Low Cost, +2.7V to 5.5V, 260MHz Rail-to-Rail Amplifier
Parameter
Supply Voltage
Input Voltage Range
Min
0
-V
s
-0.5V
Max
+6
+V
s
+0.5V
Unit
V
V
®
Reliability Information
Parameter
Junction Temperature
Storage Temperature Range
Lead Temperature (Soldering, 10s)
Package Thermal Resistance
8-Lead SOIC
Notes:
Package thermal resistance (θ
JA
), JDEC standard, multi-layer test boards, still air.
Min
-65
Typ
Max
175
150
260
Unit
°C
°C
°C
°C/W
100
ESD Protection
Product
Human Body Model (HBM)
Charged Device Model (CDM)
SOIC-8
2.5kV
2kV
Recommended Operating Conditions
Parameter
Operating Temperature Range
Min
-40
Typ
Max
+85
Unit
°C
Rev 1B
©2004-2009 CADEKA Microcircuits LLC
www.cadeka.com
3