Data Sheet
Absolute Maximum Ratings
The safety of the device is not guaranteed when it is operated above the “Absolute Maximum Ratings”. The device should
not be operated at these “absolute” limits. Adhere to the “Recommended Operating Conditions” for proper device func-
tion. The information contained in the Electrical Characteristics tables and Typical Performance plots reflect the operating
conditions noted on the tables and plots.
Comlinear CLC1201
Instrumentation Amplifier
Parameter
Supply Voltage
Input Voltage Range
Differential Input Voltage, G = 1 to 10
Differential Input Voltage, G > 10
Load Resistance
Min
0
-V
s
Max
±18
+V
s
25
≤ 0.05 (R
G
+ 800) + 1
Unit
V
V
V
V
kΩ
0.001
Reliability Information
Parameter
Junction Temperature
Storage Temperature Range
Lead Temperature (Soldering, 10s)
Package Thermal Resistance
8-Lead SOIC
8-Lead DIP
Notes:
Package thermal resistance (q
JA
), JDEC standard, multi-layer test boards, still air.
Min
-65
Typ
Max
150
150
260
Unit
°C
°C
°C
°C/W
°C/W
100
TBD
ESD Protection
Product
Human Body Model (HBM)
Charged Device Model (CDM)
SOIC-8
1.5kV
2kV
DIP-8
TBD
TBD
Rev 1C
Recommended Operating Conditions
Parameter
Operating Temperature Range
Supply Voltage Range
Min
-40
±2.3
Typ
Max
+85
±18
Unit
°C
V
©2011 CADEKA Microcircuits LLC
www.cadeka.com
5