Data Sheet
Absolute Maximum Ratings
The safety of the device is not guaranteed when it is operated above the “Absolute Maximum Ratings”. The device
should not be operated at these “absolute” limits. Adhere to the “Recommended Operating Conditions” for proper device
function. The information contained in the Electrical Characteristics tables and Typical Performance plots reflect the
operating conditions noted on the tables and plots.
CDK1307
Ultra Low Power, 10/20/40/65/80/100MSPS, 12/13-bit ADCs
Parameter
AVDD
DVDD
AVSS, DVSSCK, DVSS, OVSS
OVDD, OVSS
CLKP, CLKN
Analog inputs and outpts (IPx, INx)
Digital inputs
Digital outputs
Min
-0.3
-0.3
-0.3
-0.3
-0.3
-0.3
-0.3
-0.3
Max
+2.3
+2.3
+0.3
+3.9
+3.9
+2.3
+3.9
+3.9
Unit
V
V
V
V
V
V
V
V
Reliability Information
Parameter
Junction Temperature
Storage Temperature Range
Lead Temperature (Soldering, 10s)
Min
-60
J-STD-020
Typ
Max
TBD
+150
Unit
°C
°C
ESD Protection
Product
Human Body Model (HBM)
QFN-40
2kV
Recommended Operating Conditions
Parameter
Operating Temperature Range
Min
-40
Typ
Max
+85
Unit
°C
Rev 1A
©2009 CADEKA Microcircuits LLC
www.cadeka.com