Data Sheet
Absolute Maximum Ratings
The safety of the device is not guaranteed when it is operated above the “Absolute Maximum Ratings”. The device
should not be operated at these “absolute” limits. Adhere to the “Recommended Operating Conditions” for proper de-
vice function. The information contained in the Electrical Characteristics tables and Typical Performance plots reflect the
operating conditions noted on the tables and plots.
CDK1304
10-bit, 25 MSPS 135mW A/D Converter
Parameter
Supply Voltages
AV
DD
DV
DD
Input Voltages
Analog input
V
Ref
CLK input
AV
DD
– DV
DD
AGND – DGND
Digital Outputs
Min
Max
+6
+6
Unit
V
V
V
V
V
mV
mV
mA
-0.5
0
-100
-100
AV
DD
+0.5
AV
DD
V
DD
100
100
10
Reliability Information
Parameter
Storage Temperature Range
Min
-65
Typ
Max
+150
Unit
°C
Recommended Operating Conditions
Parameter
Operating Temperature Range
Junction Temperature Range
Lead Temperature (soldering 10 seconds)
Min
0
Typ
Max
+70
+175
+300
Unit
°C
°C
°C
REV 1A
©2008 CADEKA Microcircuits LLC
www.cadeka.com
3