欢迎访问ic37.com |
会员登录 免费注册
发布采购

SQ100-48-3.3N 参数 Datasheet PDF下载

SQ100-48-3.3N图片预览
型号: SQ100-48-3.3N
PDF下载: 下载PDF文件 查看货源
内容描述: 48V输入3.3V输出25A [48Vin 3.3Vout 25A]
分类和应用:
文件页数/大小: 16 页 / 648 K
品牌: BTCPOWER [ BROADBAND TELCOM POWER, INC. ]
 浏览型号SQ100-48-3.3N的Datasheet PDF文件第7页浏览型号SQ100-48-3.3N的Datasheet PDF文件第8页浏览型号SQ100-48-3.3N的Datasheet PDF文件第9页浏览型号SQ100-48-3.3N的Datasheet PDF文件第10页浏览型号SQ100-48-3.3N的Datasheet PDF文件第12页浏览型号SQ100-48-3.3N的Datasheet PDF文件第13页浏览型号SQ100-48-3.3N的Datasheet PDF文件第14页浏览型号SQ100-48-3.3N的Datasheet PDF文件第15页  
TM  
Technical Specification  
BTCPower  
SQ100-48-3.3,  
SQ100-48-3.3N  
Data Sheet  
SQO100-48-3.3, SQO100-48-3.3N  
48Vin 3.3Vout 25A  
Start up information  
Scenario #1: Initial Start up from power supply  
On/Off function enabled, the unit starts via input voltage Vin  
See Fig 9.  
Time  
Comments  
t0 On/Off pin is On: system front-end power is switched  
on, Vin to unit begins to rise.  
t1 Vin crosses Under voltage lockout protection circuit  
threshold: the unit enabled to be on  
t2 The unit begins to turn on ( unit turn-on delay).  
t3  
Unit output voltage reaches 100% of normal  
voltage.  
For this example, the unit total start up time (t3- t1) is  
typically 45ms.  
Scenario #2: Initial Start up using On/Off Pin  
With Vin previously powered, the unit starts via On/Off pin.  
See Fig 10.  
Fig 9. Start up waveform  
Time  
t0  
Comments  
Vin at nominal value.  
t1  
Arbitrary time when On/Off pin is enabled (Unit  
enabled)  
t2  
t3  
End of unit turn-on delay  
Unit Vout reaches 100% of nominal voltage.  
For this example, the unit total start up time (t3- t1) is  
typically 70ms.  
Scenario #3: Turn-off and restart using On/Off Pin  
With Vin previously powered, the unit is disabled and then  
enabled via On/Off pin. See Fig 11.  
Time  
Comments  
t0  
Vin and Vout are at nominal values, On/Off pin  
On.  
Fig 10. Start up using On/Off pin  
t1  
On/Off pin arbitrarily disabled, the unit output  
falls to zero. Turn-on inhibit delay period  
(100ms) is initiated, and On/Off pin action is  
internally inhibited.  
t2  
On/Off pin is externally re-enabled.  
If (t2- t1) £ 100ms, external action of On/Off pin  
Is locked out by start up inhibit timer.  
If (t2- t1) > 100ms, On/Off pin is On, the unit  
begins turn-on; if off, the unit awaits On/Off pin  
On signal; see Fig 11.  
t3  
Unit Vout reaches 100% of nominal voltage.  
For the condition, (t2- t1) £ 100ms, the unit total start  
up time (t5- t2) is typically 200ms. For (t2- t1) >  
100ms , start up should be typically 45ms after release  
of On/Off pin.  
Fig 11. Turn off and restart using On/Off pin  
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A.  
P 11 of 16  
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS SQ100-48-3.3, SQO100-48-3.3 Rev1 4-2-03