欢迎访问ic37.com |
会员登录 免费注册
发布采购

HBO17A-48-15 参数 Datasheet PDF下载

HBO17A-48-15图片预览
型号: HBO17A-48-15
PDF下载: 下载PDF文件 查看货源
内容描述: 48VIN 15Vout 17A [48Vin 15Vout 17A]
分类和应用:
文件页数/大小: 7 页 / 274 K
品牌: BTCPOWER [ BROADBAND TELCOM POWER, INC. ]
 浏览型号HBO17A-48-15的Datasheet PDF文件第1页浏览型号HBO17A-48-15的Datasheet PDF文件第2页浏览型号HBO17A-48-15的Datasheet PDF文件第3页浏览型号HBO17A-48-15的Datasheet PDF文件第5页浏览型号HBO17A-48-15的Datasheet PDF文件第6页浏览型号HBO17A-48-15的Datasheet PDF文件第7页  
Prelim. Specification
HBO17A-48-15
48Vin
15Vout 17A
BTCPower
TM
Basic operation and functions
The
HBO / HBP family
uses planar transformer
technology to achieve high output current. The
whole unit switches at the fixed frequency for a
predictable EMI performance. The
HBO / HBP
Brick
has many standard controls and protection
functions.
Input Power ( pin1, pin4 )
Input power Vin(+) must be connected to Positive
input voltage pin1; Input power Vin(-) must be
connected to Negative input voltage pin4.
Output Power ( pin9, pin5 )
Output power Vout(+) must be connected to
Positive output voltage pin9; Output power
Vout(-) must be connected to Negative output
voltage pin5.
On/Off ( pin 2 )
Permits the user to maintain unit On/Off, in order
to properly sequence different power supplies
and reduce power consumption during the
standby condition. There are two remote control
options available, positive logic and negative logic
is referenced to Vin(-), and typical connections
are shown in Fig 1.
Pin 2 is the "Enable" pin, connecting a TTL
compatible pin. A TTL control signal to this pin,
according to the specification, will turn the unit on
or off.
The positive logic version turns on when pin 2 is
at logic high, and turns off when pin 2 is at logic
low. The unit is on when pin 2 is left open.
The negative logic version turns on when pin 2 is
at logic low and turns off when pin 2 is at logic
high. The pin 2 can be directed to Vin(-), to
enable automatic turn on to the unit without the
need of an external control signal.
Remote Sense ( pin 8, pin 6 )
Permits the user to maintain the accurate output
voltage at the remote load terminals regardless of
the line drop.
The Sense(-) (pin6) and Sense(+) (pin8) should
be connected at the load or at the point where the
regulation is needed. ( shown on Fig. 2)
Fig 2: Remote Sense Circuit
Fig. 1: Typical Circuit for On/Off Function
The remote sense feature of the unit
compensates for voltage drop occurring between
the output pins of the unit and load. The Sense(-)
(pin5) and Sense(+)(pin7) should be connected at
the load or at the point where regulation is
required.
Broadband TelCom Power, Inc.
1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A.
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com •
PS HBO17A-48-15 Re2 16-1-04