欢迎访问ic37.com |
会员登录 免费注册
发布采购

TBU-CA065-200-WH 参数 Datasheet PDF下载

TBU-CA065-200-WH图片预览
型号: TBU-CA065-200-WH
PDF下载: 下载PDF文件 查看货源
内容描述: RS - 485端口保护 [RS-485 Port Protection]
分类和应用: 电信集成电路电信电路电信保护电路电视PC
文件页数/大小: 2 页 / 1153 K
品牌: BOURNS [ BOURNS ELECTRONIC SOLUTIONS ]
 浏览型号TBU-CA065-200-WH的Datasheet PDF文件第1页  
RS-485 Port Protection Evaluation Board 1  
Performance Graphs  
Run  
Trig’d  
PreVu  
Trig?  
T
T
T
T
1
2
4
Ch1 RMS  
126.7 V  
Ch1 Max  
508 V  
1
4
Ch4 Max  
371.2 mA  
Ch4 Min  
-359.9 mA  
Ch4 Max  
1.74 A  
Ch1 200 V  
Ch2  
Ch4  
20.0 V  
200 mAΩ  
M 2.00 ms A Line  
-3.98 V  
Ch1 200 V  
M
200 ns  
A
Ch1  
-172 V  
Ch4  
1.00 AΩ  
T
27.20 %  
T
31.00 %  
Ch 1: Surge generator  
Ch 1: AC power generator  
Ch 2: Voltage on protected side of world (downstream  
of TBU® device at SMBJ12CA TVS diode side)  
The ohm unit following the current units  
shown for Channel 4 (i.e. AOhm)  
indicates that a 50 ohm termination was  
used internal to the oscilloscope  
The ohm unit following the current units  
shown for Channel 4 (i.e. AOhm)  
indicates that a 50 ohm termination was  
used internal to the oscilloscope  
Ch 2: Consumed current (TBU® HSP Trigger current)  
Note: The noise generated by the GDT when it fires  
causes a ground bounce and is reflected in current  
measurement at the time the GDT device is triggered.  
Ch 4: Current consumed (TBU® HSP trigger current)  
Figure 3  
Power Cross 120 V  
Figure 4  
Slew Rate 1 KV/µs  
rms  
Reference  
PreVu  
T
T
For more information on implementing advanced circuit  
protection technologies for RS-485 ports, please review the  
Bourns® RS-485 application note:  
1
Ch1 Max  
625 V  
http://www.bourns.com/data/global/pdfs/Bourns_RS-485_AppNote.pdf  
Ch4 Max  
1.64 A  
4
Ch1 200 V  
M
200 ns  
A
Ch1  
312 V  
Ch4  
1.00 AΩ  
T
30.40 %  
Ch 1: Surge generator  
For further technical support  
and for complete circuit protection solutions,  
please visit  
The ohm unit following the current units  
shown for Channel 4 (i.e. AOhm)  
indicates that a 50 ohm termination was  
used internal to the oscilloscope  
Ch 2: Consumed current (TBU® HSP Trigger current)  
Note: The noise generated by the GDT when it fires  
causes a ground bounce and is reflected in current  
measurement at the time the GDT device is triggered.  
Figure 5  
Slew Rate 5 KV/µs  
www.bourns.com  
“TBU”is a registered trademark of Bourns, Inc. in the U.S., Taiwan and European Community.  
“Bourns”is a registered trademark of Bourns, Inc. in the U.S. and other countries.  
COPYRIGHT© 2011 • BOURNS, INC. • 11/11 • e/FU1106  
11/11 • FU1106  
 复制成功!