TBU
™
C650 and C850 Protectors
Reference Application
The C-series devices are general use protectors used in a wide variety of applications. The following diagram is one common
configuration example of C-series device placement. A cost-effective protection solution combines Bourns
®
TBU
™
protection
devices with a pair of MOVs or Bourns
®
GDTs. The figure below demonstrates the operational characteristics of the circuit.
V2
OVP
OVP
Line
V1
TBU
™
Device
Equip.
Line
TBU
™
Device
Common Configuration Diagram
3
2
1
1 ms/div.
Ch1 V1
Ch2 V2
Ch3 Current
C850 with G5200AS 4000 V Lightning 10/700 µsec, 150 A
Asia-Pacific:
Tel: +886-2 2562-4117 • Fax: +886-2 2562-4116
Europe:
Tel: +41-41 768 5555 • Fax: +41-41 768 5510
The Americas:
Tel: +1-951 781-5500 • Fax: +1-951 781-5700
www.bourns.com
200 mA/div.
REV. 03/10
COPYRIGHT©2008, BOURNS, INC. LITHO IN U.S.A. e 11/08 FU0801
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.