TISP61089B High Voltage Ringing SLIC Protector  
‘1089 Section 4.5.11 - Current-Limiting Protector Testing (Continued)  
The test generator has a voltage source that can be varied from zero to 600 V rms and an output resistance of 20 to each conductor. Table 4  
shows the range of currents conducted by the TISP61089B.  
Table 4. Wiring Simulator Testing  
TISP61089B I  
A (peak)  
Open-Circuit  
RMS Voltage  
V
Short-Circuit  
RMS Current  
A
Source  
Resistance  
TM  
AC Duration  
s
Tes t  
Primary  
Fitted  
Connections  
R = 25  
R = 40  
s
s
900  
0 to 600  
0 to 30  
Transverse & Longitudinal  
No  
20  
0 to 2x 19 0 to 2x 14  
‘1089 Section 4.5.12 - First-Level Power Fault Testing  
Table 5 shows the nine tests used for this section. The TISP61089B will survive these peak current values as they are lower than the  
TISP61089B current-time ratings.  
Table 5. First-Level Power Fault Currents  
TISP61089B I  
A (peak)  
Open-circuit  
RMS Voltage  
V
Short-circuit  
RMS Current  
A
No  
of  
Source  
Resistance  
TM  
Test  
#
AC Duration  
s
Te st  
Primary  
Fitted  
Connections  
Tests  
R = 25  
s
R = 40 Ω  
s
Transverse &  
Longitudinal  
1
2
900  
900  
50  
0.33  
0.17  
1
1
No  
No  
150  
600  
2x0.40  
2x0.23  
2x0.37  
2x0.22  
Transverse &  
Longitudinal  
100  
200  
400  
600  
0.33  
0.67  
1.00  
60  
60  
60  
2x0.45  
2x0.90  
2x1.36  
2x0.44  
2x0.89  
2x1.33  
Transverse &  
Longitudinal  
3
1
No  
600  
4
5
1
5
1000  
600  
1
60  
60  
Longitudinal  
Differential  
Yes  
No  
1000  
2x1.38  
2x0.12  
2x1.30  
2x0.12  
0.09  
Capacitive  
Transverse &  
Longitudinal  
6
7
30  
2
600  
600  
0.5  
2.2  
1
1
No  
No  
1200  
273  
2x0.69  
2x2.85  
2x0.68  
2x2.71  
Transverse &  
Longitudinal  
Transverse &  
Longitudinal  
8
9
1
600  
3.0  
5
1
1
No  
200  
200  
2x3.77  
2x6.28  
2x3.54  
2x5.89  
0.5  
1000  
Longitudinal  
Yes  
NOTES: 1. If the equipment contains a voltage-limiting device or a current-limiting device, tests 1, 2 and 3 are repeated at a level just below  
the thresholds of the limiting devices.  
2. Test 5 uses a special circuit with transformer coupled a.c. and capacitive feed.  
3. Tests 1 through 5 are requirements and the equipment shall not be damaged after these tests.  
4. Tests 6 through 9 are desirable objectives and the equipment can be damaged after these tests.  
‘1089 Section 4.5.13 - Second-Level Power Fault Testing for Central Office Equipment  
Table 6 shows the five tests used for this section. Columns 9 and 10 show the prospective currents for these tests using R values of 25 and  
S
40 . The two most stressful tests of this section are test 1 and test 2. As shown in Table 6, the peak currents for these tests are 2x17 A and  
2x7.7 A respectively. With the exception of test 5, all the other tests require the series overcurrent protection to operate before the TISP61089B  
current-time ratings are exceeded. In the case of test 2, with an R of 25 , the overcurrent protection must operate within the initial a.c. half  
S
cycle to prevent damage.  
OCTOBER 2000 - REVISED JULY 2008  
Specifications are subject to change without notice.  
Customers should verify actual device performance in their specific applications.