TISP61089B High Voltage Ringing SLIC Protector
‘1089 Section 4.5.11 - Current-Limiting Protector Testing (Continued)
The test generator has a voltage source that can be varied from zero to 600 V rms and an output resistance of 20 Ω to each conductor. Table 4
shows the range of currents conducted by the TISP61089B.
Table 4. Wiring Simulator Testing
TISP61089B I
A (peak)
Open-Circuit
RMS Voltage
V
Short-Circuit
RMS Current
A
Source
Resistance
Ω
TM
AC Duration
s
Tes t
Primary
Fitted
Connections
R = 25
Ω
R = 40 Ω
s
s
900
0 to 600
0 to 30
Transverse & Longitudinal
No
20
0 to 2x 19 0 to 2x 14
‘1089 Section 4.5.12 - First-Level Power Fault Testing
Table 5 shows the nine tests used for this section. The TISP61089B will survive these peak current values as they are lower than the
TISP61089B current-time ratings.
Table 5. First-Level Power Fault Currents
TISP61089B I
A (peak)
Open-circuit
RMS Voltage
V
Short-circuit
RMS Current
A
No
of
Source
Resistance
Ω
TM
Test
#
AC Duration
s
Te st
Primary
Fitted
Connections
Tests
R = 25
s
Ω
R = 40 Ω
s
Transverse &
Longitudinal
1
2
900
900
50
0.33
0.17
1
1
No
No
150
600
2x0.40
2x0.23
2x0.37
2x0.22
Transverse &
Longitudinal
100
200
400
600
0.33
0.67
1.00
60
60
60
2x0.45
2x0.90
2x1.36
2x0.44
2x0.89
2x1.33
Transverse &
Longitudinal
3
1
No
600
4
5
1
5
1000
600
1
60
60
Longitudinal
Differential
Yes
No
1000
2x1.38
2x0.12
2x1.30
2x0.12
0.09
Capacitive
Transverse &
Longitudinal
6
7
30
2
600
600
0.5
2.2
1
1
No
No
1200
273
2x0.69
2x2.85
2x0.68
2x2.71
Transverse &
Longitudinal
Transverse &
Longitudinal
8
9
1
600
3.0
5
1
1
No
200
200
2x3.77
2x6.28
2x3.54
2x5.89
0.5
1000
Longitudinal
Yes
NOTES: 1. If the equipment contains a voltage-limiting device or a current-limiting device, tests 1, 2 and 3 are repeated at a level just below
the thresholds of the limiting devices.
2. Test 5 uses a special circuit with transformer coupled a.c. and capacitive feed.
3. Tests 1 through 5 are requirements and the equipment shall not be damaged after these tests.
4. Tests 6 through 9 are desirable objectives and the equipment can be damaged after these tests.
‘1089 Section 4.5.13 - Second-Level Power Fault Testing for Central Office Equipment
Table 6 shows the five tests used for this section. Columns 9 and 10 show the prospective currents for these tests using R values of 25 Ω and
S
40 Ω. The two most stressful tests of this section are test 1 and test 2. As shown in Table 6, the peak currents for these tests are 2x17 A and
2x7.7 A respectively. With the exception of test 5, all the other tests require the series overcurrent protection to operate before the TISP61089B
current-time ratings are exceeded. In the case of test 2, with an R of 25 Ω, the overcurrent protection must operate within the initial a.c. half
S
cycle to prevent damage.
OCTOBER 2000 - REVISED JULY 2008
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.