BMA253  
Data sheet  
Page 32  
The parameters (0x2A) tap_shock and (0x2A) tap_quiet apply to both single tap and double tap  
detection, while (0x2A) tap_dur applies to double tap detection only. Within the duration of  
(0x2A) tap_shock any slope exceeding (0x2B) tap_th after the first event is ignored. Contrary to  
this, within the duration of (0x2A) tap_quiet no slope exceeding (0x2B) tap_th must occur,  
otherwise the first event will be cancelled.  
4.7.6.1 Single tap detection  
A single tap is detected and the single tap interrupt is generated after the combined durations of  
(0x2A) tap_shock and (0x2A) tap_quiet, if the corresponding slope conditions are fulfilled. The  
interrupt is cleared after a delay of 12.5 ms.  
Do not map single-tap to any INT pin if you do not want to use it.  
4.7.6.2 Double tap detection  
A double tap interrupt is generated if an event fulfilling the conditions for a single tap occurs  
within the set duration in (0x2A) tap_dur after the completion of the first tap event. The interrupt  
is automatically cleared after a delay of 12.5 ms.  
4.7.6.3 Selecting the timing of tap detection  
For each of parameters (0x2A) tap_shock and (0x2A) tap_quiet two values are selectable. By  
writing ´0´ (´1´) to bit (0x2A) tap_shock the duration of (0x2A) tap_shock is set to 50 ms (75  
ms). By writing ´0´ (´1´) to bit (0x2A) tap_quiet the duration of (0x2A) tap_quiet is set to 30 ms  
(20 ms).  
The length of (0x2A) tap_dur can be selected by setting the (0x2A) tap_dur bits according to  
Table 11  
Table 11: Selection of tap_dur  
(0x2A)  
tap_dur  
length of tap_dur  
000b  
001b  
010b  
011b  
100b  
101b  
110b  
111b  
50 ms  
100 ms  
150 ms  
200 ms  
250 ms  
375 ms  
500 ms  
700 ms  
BST-BMA253-DS000-01 | Revision 1.0 | August 2015  
Bosch Sensortec  
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to  
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.  
Note: Specifications within this document are subject to change without notice.  
 