RATINGS AND CHARACTERISTIC CURVES
3R12 --- 3R16
FIG.1 -- FORWARD DERATING CURVE
AVERAGE FORWARD RECTIFIED CURRENT
AMPERES
FIG.2 -- TYPICAL FORWARD CHARACTERISTICS
INSTANTANEOUS FORWARD CURRENT
AMPERES
100
3.0
10
1.0
Single Phase
Half W ave 60H
Z
Resistive or
Inductive Load
1.0
0.1
0
25
50
75
100
125
150
175
200
T
J
=25
Pulse W idth=300
µ
s
.01
0.4 0.6 0.8
1.0
1.2 1.4 1.6 1.8
AMBIENT TEMPERATURE,
INSTANTANEOUS FORWARD VOLTAGE, VOLTS
FIG.3 -- PEAK FORWARD SURGE CURRENT
FIG.4 -- TYPICAL JUNCTION CAPACITANCE
PEAK FORWARD SURGE CURRENT
AMPERES
100
150
T
J
=125
8.3ms Single Half
Sine - Wave
100
CAPACITANCE,pF
10
50
T
J
=25
0
1
10
100
0
1
4
10
100
NUMBER OF CYCLES AT 60Hz
REVERSE VOLTAGE,VOLTS
www.galaxycn.com
Document Number 0263005
BL
GALAXY ELECTRICAL
2.