NON-ISOLATED DC/DC CONVERTERS
POWER PRODUCTS
12V Input / 1.5V – 5.0V Output / 3A
BP02x7AH-03A
Output Specifications
Parameter
Module
Symbol
Min
Typical
Max
Units
Transient Response 4
∆V 50% to 100% of Max Load
Settling Time
100
40
200
80
mV
µs
Ts
Ts
5.0V
∆V 100% to 50% of Max Load
Settling Time
100
40
200
80
mV
µs
Transient Response 4
∆V 50% to 100% of Max Load
Settling Time
80
40
80
40
150
80
mV
µs
Ts
Ts
3.3V
2.5V
1.8V
1.5V
∆V 100% to 50% of Max Load
Settling Time
150
80
mV
µs
Transient Response 4
∆V 50% to 100% of Max Load
Settling Time
70
40
70
40
100
80
mV
µs
Ts
Ts
∆V 100% to 50% of Max Load
Settling Time
100
80
mV
µs
Transient Response 4
∆V 50% to 100% of Max Load
Settling Time
70
40
70
40
100
80
mV
µs
Ts
Ts
∆V 100% to 50% of Max Load
Settling Time
100
80
mV
µs
Transient Response 4
∆V 50% to 100% of Max Load
Settling Time
70
40
70
40
100
80
mV
µs
Ts
Ts
∆V 100% to 50% of Max Load
Settling Time
100
80
mV
µs
Note: All specifications are typical at nominal input, full load at 25° C unless otherwise stated.
4. di/dt = 0.5A/1µS, Ta = 25° C without external load capacitance.
©2003 Bel Fuse Inc. Specifications subject to change without notice. 01.03
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
page 4