NON-ISOLATED DC/DC CONVERTERS  
2.4 Vdc - 5.5 Vdc Input, 0.6 Vdc - 3.63 Vdc /6 A Outputs  
January 13, 2011  
Absolute Maximum Ratings  
Parameter  
Bel Power, Inc. , a subsidiary of Bel Fuse, Inc.  
Unit  
V
Min  
-0.3  
-40  
-55  
Typ  
Max  
6
Notes  
Continuous Input Voltage  
Operating Ambient Temperature  
Storage Temperature  
-
-
-
85  
°C  
°C  
125  
Note: Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These  
are absolute stress ratings only, functional operation of the device is not implied at these or any other  
conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute  
maximum ratings for extended periods can adversely affect the device reliability.  
Input Specifications  
Parameter  
Min  
Typ  
Max  
Unit  
Notes  
Operating Input Voltage  
2.4  
-
5.5  
V
Input Current (full load)  
Input Current (no load)  
-
-
6.5  
A
VIN=2.4V to 5.5V  
Vo=0.6V  
Vo=3.3V  
-
-
30  
75  
-
-
mA VIN=5.0V, module enabled  
mA  
Input Stand-by Current  
-
2.2  
-
mA VIN = 5.0Vdc, module disabled  
5Hz to 20MHz, 1μH source  
mA impedance; VIN =0 to 5.5V, IO= IOmax  
See Test Configurations  
A2s  
dB  
V
Input Reflected Ripple Current  
(pk-pk)  
-
25  
-
;
I2t Inrush Current Transient  
Input Ripple Rejection (120Hz)  
Turn-on Threshold  
-
-
-
40  
-
1
-
-
2.2  
-
Turn-off Threshold  
1.75  
0.08  
-
V
Hysteresis  
-
0.2  
V
CAUTION: This converter is not internally fused. An input line fuse must be used in application.  
This power module can be used in a wide variety of applications, ranging from simple standalone operation to  
an integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not  
included; however, to achieve maximum safety and system protection, always use an input line fuse. The  
safety agencies require a fast-acting fuse with a maximum rating of 6A. Based on the information provided in  
this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can  
be used. Refer to the fuse manufacturer’s data sheet for further information.  
Note: Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and  
temperature conditions.  
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 Tel 201-432-0463 Fax 201-432-9542 www.belfuse.com  