NON-ISOLATED DC/DC CONVERTERS
2.4 Vdc - 5.5 Vdc Input, 0.6 Vdc - 3.63 Vdc /6 A Outputs
January 13, 2011
Absolute Maximum Ratings
Parameter
Bel Power, Inc. , a subsidiary of Bel Fuse, Inc.
Unit
V
Min
-0.3
-40
-55
Typ
Max
6
Notes
Continuous Input Voltage
Operating Ambient Temperature
Storage Temperature
-
-
-
85
°C
°C
125
Note: Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These
are absolute stress ratings only, functional operation of the device is not implied at these or any other
conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute
maximum ratings for extended periods can adversely affect the device reliability.
Input Specifications
Parameter
Min
Typ
Max
Unit
Notes
Operating Input Voltage
2.4
-
5.5
V
Input Current (full load)
Input Current (no load)
-
-
6.5
A
VIN=2.4V to 5.5V
Vo=0.6V
Vo=3.3V
-
-
30
75
-
-
mA VIN=5.0V, module enabled
mA
Input Stand-by Current
-
2.2
-
mA VIN = 5.0Vdc, module disabled
5Hz to 20MHz, 1μH source
mA impedance; VIN =0 to 5.5V, IO= IOmax
See Test Configurations
A2s
dB
V
Input Reflected Ripple Current
(pk-pk)
-
25
-
;
I2t Inrush Current Transient
Input Ripple Rejection (120Hz)
Turn-on Threshold
-
-
-
40
-
1
-
-
2.2
-
Turn-off Threshold
1.75
0.08
-
V
Hysteresis
-
0.2
V
CAUTION: This converter is not internally fused. An input line fuse must be used in application.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to
an integrated part of sophisticated power architecture. To preserve maximum flexibility, internal fusing is not
included; however, to achieve maximum safety and system protection, always use an input line fuse. The
safety agencies require a fast-acting fuse with a maximum rating of 6A. Based on the information provided in
this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can
be used. Refer to the fuse manufacturer’s data sheet for further information.
Note: Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and
temperature conditions.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
2