TYPICAL PERFORMANCE CURVES
(CONT)
At T
A
= +25°C, V
S
=
±15V,
R
L
= 2kΩ, unless otherwise noted.
OFFSET VOLTAGE PRODUCTION DISTRIBUTION
18
16
Typical production
distribution of packaged
units.
12
10
OFFSET VOLTAGE DRIFT
PRODUCTION DISTRIBUTION
Typical production
distribution of packaged
units.
Percent of Amplifiers (%)
Percent of Amplifiers (%)
14
12
10
8
6
4
2
0
8
6
4
2
0
–2000
–1800
–1600
–1400
–1200
–1000
–800
–600
–400
–200
0
200
400
600
800
1000
1200
1400
1600
1800
2000
0.5
1.5
2.5
3.5
4.5
5.5
6.5
7.5
8.5
9.5
10.5
11.5
Offset Voltage (V)
Offset Voltage Drift (µV/°C)
SMALL-SIGNAL STEP RESPONSE
G =1, C
L
= 100pF
LARGE-SIGNAL STEP RESPONSE
G = 1, C
L
= 100pF
50mV/div
5V/div
200ns/div
1µs/div
SETTLING TIME vs CLOSED-LOOP GAIN
100
SMALL-SIGNAL OVERSHOOT
vs LOAD CAPACITANCE
60
50
G = +1
G = –1
Settling Time (µs)
Overshoot (%)
10
0.01%
40
30
20
10
0.1%
1
G = ±10
0.1
±1
±10
±100
±1000
Closed-Loop Gain (V/V)
0
100pF
1nF
Load Capacitance
12.5
10nF
®
7
OPA134/2134/4134