SPECIFICATIONS
PARAMETER
GENERAL (Cont)
Efficiency
DCP010505
DCP010505D
DCP010512
DCP010512D
DCP010515
DCP010515D
MTTF
(3)
(CONT)
DCP0105 SERIES
CONDITIONS
MIN
TYP
MAX
UNITS
At T
A
= +25°C, V
S
= +5V, unless otherwise specified.
100% Full Load
10% Full Load
100% Full Load
10% Full Load
100% Full Load
10% Full Load
100% Full Load
10% Full Load
100% Full Load
10% Full Load
100% Full Load
10% Full Load
T
A
= +85°C
T
A
= +55°C
T
A
= +25°C
158,000
3,050,000
108,000,000
71
40
66
47
72
38
72
36
73
40
75
38
%
%
%
%
%
%
%
%
%
%
%
%
hrs
hrs
hrs
Weight
THERMAL SHUTDOWN
Internal Controller IC Temperature
Shutdown Current
TEMPERATURE RANGE
Operating
14-Pin PDIP
115
1.08
140
3
–40
+100
g
°C
mA
°C
NOTES: (1) 100% load current = 1W/V
NOM
typical. (2) Rated working voltage = 130Vr ms (IEC950 Convention). (3) Life test data.
EMC SPECIFICATIONS
Specifications and Related Documents
The DCP010505 was tested to and complied with the limits of the following EMC specifications:
prEN55022 (1992)
Conducted RF emission, telecomm lines.
EN55022 (1995)
ENV50140 (1993)
ENV50141 (1993)
EN61000-4-2 (1995)
EN61000-4-4 (1995)
EN61000-4-8 (1994)
Limits and methods of measurement of radio interference characteristics of information technology equipment.
Electromagnetic compatibility. Basic immunity standard. Radiated RF immunity.
Electromagnetic compatibility. Basic immunity standard. Conducted RF immunity.
Electromagnetic compatibility, Part 4. Testing and measurement techniques, Section 2. Electrostatic
discharge.
Electromagnetic compatibility, Part 4. Testing and measurement techniques, Section 4. Electrical fast
transient bursts.
Electromagnetic compatibility, Part 4. Testing and measurement techniques, Section 8. Power frequency
magnetic field immunity.
List of Tests
The following is a list of tests which were required for compliance with the above specifications:
Conducted Emission Test
150kHz to 30MHz, power and output lines, Class B limits applying. DC/DC loads of
0%, 8%, and 120% applying.
Radiated Emission Test
Radiated Immunity Test, Electric Field
Radiated Immunity Test, Electric Field
Electrostatic Discharge Test
Electrical Fast Transient Tests
Conducted RF Immunity Tests
Radiated Immunity Test, Magnetic Field
30MHz to 1000MHz, Class B limits applying. DC/DC loads of 0%, 8%, and 120%
applying.
80MHz to 1000MHz, 10V/m, 1kHz 80% AM.
900MHz, 10V/m, 200Hz 100% PM.
4kV, HCP/VCP indirect discharge only.
2kV power lines, 2kV signal lines.
150kHz to 80MHz, power and output lines, 10Vrms, 1kHz 80% AM.
50Hz, 30A/m
®
3
DCP0105