MODES OF OPERATION  
Hold and Reset Switches  
To use the Hold switch, connect the input current to the “Sw  
In” pin. The Hold switch disconnects the input current, and  
holds the output voltage at a fixed level. For direct input,  
connect the input current to the “In” pin that bypasses the  
Hold switch and connects directly to the input summing  
junction. If the Hold switch is not used, the switch should be  
in the off mode and the “Sw In” pin should be connected to  
analog common.  
The three basic modes of operation of each integrator are  
controlled by the Hold and Reset switches. In Integrate  
mode, the output voltage integrates negatively toward –10V.  
In Hold mode, the output voltage remains at the present  
value, except for output droop. In Reset mode, the integra-  
tion capacitor is discharged and the output voltage is driven  
to analog common. See Figure 4.  
SWITCHES  
The Reset switch is used to discharge the integration capaci-  
tor before the start of a new integration period. See Typical  
Each integrator includes four switches: a Hold switch, a  
Reset switch, and two output Select switches. See Figure 3.  
Performance Curve showing Reset Time vs CINTEGRATION  
.
Select Switches  
The two Select switches can be used to multiplex the outputs  
when multiple integrators are connected to a common bus.  
Figure 5 shows a number of ACF2101s multiplexed together  
into an A/D converter. The output settling time is deter-  
mined by the Select switch “on” resistance of 250and  
the total output capacitance. The total output capacitance  
includes the ACF2101 output capacitances plus the capaci-  
tance of the interconnections to the A/D converter.  
Hold  
Reset  
Select  
100pF  
CINTERNAL  
Reset  
Cap  
In  
Out  
Sw In  
Hold  
Sw Out  
Com  
Sw Com  
FIGURE 3. Switch Control Lines on One Channel of Two  
in ACF2101.  
HOLD  
INTEGRATE  
HOLD RST HOLD INTEGRATE  
To  
0
ADC  
Instrumentation  
Amplifier  
–10  
OFF  
HOLD  
ON  
OFF  
RESET  
ON  
MODES OF OPERATION  
MODE OF OPERATION  
SWITCH  
Integrate  
ON  
OFF  
Hold  
Reset  
Hold Switch  
Reset Switch  
OFF  
OFF  
ON/OFF  
ON  
FIGURE 5. ACF2101s in Multiplexed Operation.  
ON: Switch shorted; Logic 0 input. OFF: Switch open; Logic 1 input.  
FIGURE 4. Modes of Operation.  
®
9
ACF2101