AZ1641
RELAY ORDERING DATA
STANDARD RELAYS: DC Coil
COIL SPECIFICATIONS
Nominal Coil
VDC
6
12
24
48
110
Must Operate
VDC
4.8
9.6
19.2
38.4
88.0
Max. Continuous
VDC
6.6
13.2
26.4
52.8
121.0
Nominal Current
mA ± 10%
150.0
75.0
36.9
18.5
10.0
Coil Resistance
40.0
± 10%
160
650
2600
11,000
± 10%
± 10%
± 15%
± 15%
ORDER NUMBER*
AZ1641–2C–6D
AZ1641–2C–12D
AZ1641–2C–24D
AZ1641–2C–48D
AZ1641–2C–110D
STANDARD RELAYS: AC Coil (50/60 Hz)
COIL SPECIFICATIONS
Nominal Coil
VAC
6
12
24
48
120
220
Must Operate
VAC
4.8
9.6
19.2
38.4
96.0
176.0
Max. Continuous
VAC
7.1
14.3
28.6
57.1
143.0
261.0
Nominal Current
mA ± 10%
200.0
100.0
50.0
25.0
10.0
5.5
Coil Resistance
11.5
± 10%
46.0
± 10%
184
735
4,550
14,400
± 10%
± 10%
± 10%
± 15%
ORDER NUMBER*
AZ1641–2C–6A
AZ1641–2C–12A
AZ1641–2C–24A
AZ1641–2C–48A
AZ1641–2C–120A
AZ1641–2C–220A
* For 3PDT or 4PDT substitute “-3C” or “-4C” for “-2C”. For LED add “1” to the end of p/n.
RELAY ORDERING DATA
HEAVY DUTY RELAYS: DC Coil
COIL SPECIFICATIONS
Nominal Coil
VDC
6
12
24
48
110
Must Operate
VDC
4.8
9.6
19.2
38.4
88.0
Max. Continuous
VDC
6.6
13.2
26.4
52.8
121.0
Nominal Current
mA ± 10%
150.0
75.0
36.9
18.5
10.0
Coil Resistance
40.0
± 10%
160
650
2600
11,000
± 10%
± 10%
± 15%
± 15%
ORDER NUMBER*
AZ1641–1CT–6D
AZ1641–1CT–12D
AZ1641–1CT–24D
AZ1641–1CT–48D
AZ1641–1CT–110D
HEAVY DUTY RELAYS: AC Coil (50/60 Hz)
COIL SPECIFICATIONS
Nominal Coil
VAC
6
12
24
48
120
220
240
Must Operate
VAC
4.8
9.6
19.2
38.4
96.0
176.0
192.0
Max. Continuous
VAC
7.1
14.3
28.6
57.1
143.0
261.0
288.0
Nominal Current
mA ± 10%
200.0
100.0
50.0
25.0
10.0
5.5
5.0
Coil Resistance
11.5
± 10%
46.0
± 10%
184
735
4,550
14,400
22,000
± 10%
± 10%
± 10%
± 15%
± 15%
ORDER NUMBER*
AZ1641–1CT–6A
AZ1641–1CT–12A
AZ1641–1CT–24A
AZ1641–1CT–48A
AZ1641–1CT–120A
AZ1641–1CT–220A
AZ1641–1CT–240A
* For DPDT substitute “-2CT” for “-1CT”. For LED add “1” to the end of p/n.
9/18/14