PD035QU2
16. Reliability Test
No
Test Item
Test Condition
Ta = +80к, 240 hrs
Ta = -30к, 240 hrs
Ta = +70к, 240 hrs
Ta = -20к, 240 hrs
1
2
3
4
High Temperature Storage Test
Low Temperature Storage Test
High Temperature Operation Test
Low Temperature Operation Test
High Temperature & High Humidity
Operation Test
Ta = +60к, 90%RH, 240 hrs
5
6
кШ
к
+70 , 100 Cycles,
-20
Thermal Shock Test
(non-operating)
30 min 30 min
Frequency:10~550HZ
Amplitude: 1.3mm
Vibration Test
(non-operating)
7
Sweep:1.5G,33.3~400Hz
Vibration: Sinusoidal Wave,1Hrs for X,Y,Z direction
100G, 6ms
Direction : ̈́X, ̈́Y, ̈́Z
Cycle : 3 times
Half sinusoidal wave
150pF, 330Ө
Air : 8KV ; Contact : 6KV
Shock Test
(non-operating)
8
9
Electrostatic Discharge Test
(non-operating)
Ta: ambient temperature
Note : The protective film must be removed before temperature test.
[Criteria]
1. The test samples have recovery time for 2 hours at room temperature before the function check.
In the standard conditions, there is no display function NG issue occurred.
2. All the cosmetic specifications are judged before the reliability stress.