ATM0430D12(AZ DISPLAYS) TFT MODULE V2.1
5. RELIABILITY TEST
Item
Test Condition Item
Ta= 80 ºC 240hrs
Remark
Note 1
Note 4
High temperature
storage
Note 1
Note 4
Low temperature
storage
Ta=-30 ºC 240hrs
Ts= 70 ºC 240hrs
Note 2
Note 4
High temperature
operation
Note 1
Note 4
Low temperature
operation
Ts=-20 ºC 240hrs
High temperature/High
humidity operation
Note 4
90% RH 60ºC 240hrs
-30℃/30 min ~ +80℃/30 min for a total 100
cycles, Start with cold temperature and end
with high temperature.
Thermal Shock
Note 4
Freq:10~55~10Hz
Amplitude:1.5mm
2 hours for each direction of X,Y,Z
(6 hours for total)
Vibration test
100G 6ms,±X, ±Y, ±Z 3 times for each
direction
Mechanical shock
Random Vibration :
0.015G*G/Hz from 5-200HZ, -6dB/Octave
from 200-500HZ
Package vibration test
2 hours for each direction of X. Y. Z.
(6 hours for total)
Height:60 cm
1 corner, 3 edges, 6 surfaces
Package drop test
Electro static discharge
± 2KV, Human Body Mode, 100pF/1500Ω
Note 1: Ta is the ambient temperature of samples.
Note 2: Ts is the temperature of panel’s surface.
Note 3: In the standard condition, there shall be no practical problem that may affect the
display function. After the reliability test, the product only guarantees operation,
but don’t guarantee all of the cosmetic specification.
Note 4: Before cosmetic and function test, the product must have enough recovery time, at least 2 hours
at room temperature.
10
AZ DISPLAYS