AQM1264C-FL-YBW GRAPHIC MODULE VER1.0
CONTRAST(%)
100%
90%
(DARK)
10%
0%
(BRIGHT)
t0
tr
td
TIME
Von
Voff
Delay time to : Measured between zero and 10% with Von.
Rise time tr : Measured between 10% and 90% of LCD segment maximum response with Von
Decay time td : With voltage switches to zero and the instant LCD segment reaches 10% of its maximum
response
Ton : Time measured between the instant operating voltage is applied to display and the distant the
display reaches 90% of its maximum response.
Toff : Time measured between the instant operating voltage switches to zero and the instant the display
reaches 10% of its maximum response.
LIQUID CRYSTAL PANEL LIFE TIME
50000 hours minimum at 25℃±10℃ and 65% RH maximum.
Note: Definition of life time : the time up to occurrence of any of the following:
Contrast reduces to 30% of the initial value.
Current consumption becomes three times the initial value.
Orientation deteriorates significantly.
AZ DISPLAYS, INC.