AGM1232G SERIES GRAPHIC MODULE
9.0 RELIABILITY TEST
Evaluations and Assessment*
Current
Consumption
Storage Condition
Content
Oozing
Contrast
Other Appearances
No abnormality
Operation at high
temperature and
humidity
40º C,90%
RH,240hrs
Twice initial
value or less
More than 80% of
initial value
none
High temperature
storage
60º C,
240hrs
-20º C,
240hrs
Twice initial
value or less
Twice initial
value or less
More than 80% of
initial value
none
No abnormality
No abnormality
Low temperature
storage
More than 80% of
initial value
*Evaluations and assessment to be made two hours after returning to room temperature (25º C±5º C).