Enclosure drawing:
Pin connections
Pin # Symbol
1
N.C.
2
V
REF
3
V
S
4
RF OUT
5
N.C.
6
N.C.
7
GND
Function
No Connection
Reference Voltage
Supply Voltage
RF Output
No Connection
No Connection
Ground
Environmental conditions
Test
Visual inspection,
dimensions
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
Bump*
Free fall*
IEC 60068
Part ...
IEC 60679-1
clause ...
4.3
4.6.2
4.6.3
Test conditions
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235
±
5)°C Method 1
Test Tb Method 1A, 5s
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1
st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
2-17
2-20
2-58
2-27
2-29
2-32
4.6.8
4.6.6
4.6.9
4.6.7
Vibration, sinusoidal* 2-6
Rapid change of
temperature
Dry heat
Damp heat, cyclic*
Cold
Climatic sequence*
Damp heat, steady
state*
Endurance tests
- ageing
- extended aging
2-14
2-2
2-30
2-1
1-7
2-3
4.6.5
4.6.14
4.6.15
4.6.16
4.6.17
4.6.18
4.7.1
4.7.2
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXIOM10S
page
2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: info@axtal.com