Enclosure drawing
Pin connections
Pin # Symbol Function
P1
VC
Control Voltage (EFC)
P2 RF OUT RF Output
P3
P4
VS
N.C.
Supply Voltage
Not Connected
All
GND Ground
others
Environmental conditions
Test
IEC 60068 IEC 60679-1
Test conditions
Part ...
clause ...
Visual inspection,
dimensions
4.3
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
2-17
4.6.2
4.6.3
2-20
2-58
2-27
2-29
2-32
4.6.8
4.6.6
4.6.9
4.6.7
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Bump*
Free fall*
Vibration, sinusoidal* 2-6
Rapid change of
temperature
Dry heat
2-14
4.6.5
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
2-2
2-30
2-1
1-7
2-3
4.6.14
4.6.15
4.6.16
4.6.17
4.6.18
Damp heat, cyclic*
Cold
Climatic sequence*
Damp heat, steady
state*
GmbH & Co. KG
AXHV3003
www.axtal.com
Wasemweg 5
D-74821 Mosbach
Germany
page 2(3)
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: info@axtal.com