TAZ Series
CWR09 - MIL-PRF-55365/4 Established Reliability, COTS-Plus & Space Level
Parametric Specifications by Rating per MIL-PRF-55365/4
Typical Ripple Data by Rating
RATING & PART NUMBER REFERENCE
Cap
@ 120Hz
μF
@ 25ºC
0.22
0.47
0.68
1
1.5
3.3
4.7
6.8
DC Rated
Voltage
V
ESR @
100kHz
Ohms
DCL max
+85ºC
DF Max
+25ºC +(85/125)ºC
Power
Dissipation Ripple
25ºC
85ºC
Ripple
A
125ºC
Ripple
A
25ºC
Ripple
V
85ºC
Ripple
V
125ºC
Ripple
V
+25ºC
(μA)
+125ºC
(μA)
-55ºC
(%)
A
CWR09 P/N
AVX MIL & COTS-Plus p/n
AVX SRC9000 P/N
Case
(μA)
(%)
(%)
W
@ +85ºC @ +25ºC
(100kHz) (100kHz) (100kHz) (100kHz) (100kHz) (100kHz)
CWR09M^224*@+ TAZ A 224 * 035 C ꢀ # @ 0 ^ ++ TAZ A 224 * 035 C ꢀ L @ 9 ^ ++
CWR09M^474*@+ TAZ B 474 * 035 C ꢀ # @ 0 ^ ++ TAZ B 474 * 035 C ꢀ L @ 9 ^ ++
CWR09M^684*@+ TAZ C 684 * 035 C ꢀ # @ 0 ^ ++ TAZ C 684 * 035 C ꢀ L @ 9 ^ ++
CWR09M^105*@+ TAZ D 105 * 035 C ꢀ # @ 0 ^ ++ TAZ D 105 * 035 C ꢀ L @ 9 ^ ++
CWR09M^155*@+ TAZ E 155 * 035 C ꢀ # @ 0 ^ ++ TAZ E 155 * 035 C ꢀ L @ 9 ^ ++
CWR09M^335*@+ TAZ F 335 * 035 C ꢀ # @ 0 ^ ++ TAZ F 335 * 035 C ꢀ L @ 9 ^ ++
CWR09M^475*@+ TAZ G 475 * 035 C ꢀ # @ 0 ^ ++ TAZ G 475 * 035 C ꢀ L @ 9 ^ ++
CWR09M^685*@+ TAZ H 685 * 035 C ꢀ # @ 0 ^ ++ TAZ H 685 * 035 C ꢀ L @ 9 ^ ++
CWR09N^104*@+ TAZ A 104 * 050 C ꢀ # @ 0 ^ ++ TAZ A 104 * 050 C ꢀ L @ 9 ^ ++
CWR09N^154*@+ TAZ A 154 * 050 C ꢀ # @ 0 ^ ++ TAZ A 154 * 050 C ꢀ L @ 9 ^ ++
CWR09N^224*@+ TAZ B 224 * 050 C ꢀ # @ 0 ^ ++ TAZ B 224 * 050 C ꢀ L @ 9 ^ ++
CWR09N^334*@+ TAZ B 334 * 050 C ꢀ # @ 0 ^ ++ TAZ B 334 * 050 C ꢀ L @ 9 ^ ++
CWR09N^474*@+ TAZ C 474 * 050 C ꢀ # @ 0 ^ ++ TAZ C 474 * 050 C ꢀ L @ 9 ^ ++
CWR09N^684*@+ TAZ D 684 * 050 C ꢀ # @ 0 ^ ++ TAZ D 684 * 050 C ꢀ L @ 9 ^ ++
CWR09N^105*@+ TAZ E 105 * 050 C ꢀ # @ 0 ^ ++ TAZ E 105 * 050 C ꢀ L @ 9 ^ ++
CWR09N^155*@+ TAZ F 155 * 050 C ꢀ # @ 0 ^ ++ TAZ F 155 * 050 C ꢀ L @ 9 ^ ++
CWR09N^225*@+ TAZ F 225 * 050 C ꢀ # @ 0 ^ ++ TAZ F 225 * 050 C ꢀ L @ 9 ^ ++
CWR09N^335*@+ TAZ G 335 * 050 C ꢀ # @ 0 ^ ++ TAZ G 335 * 050 C ꢀ L @ 9 ^ ++
CWR09N^475*@+ TAZ H 475 * 050 C ꢀ # @ 0 ^ ++ TAZ H 475 * 050 C ꢀ L @ 9 ^ ++
A
B
C
D
E
35
35
35
35
35
35
35
35
50
50
50
50
50
50
50
50
50
50
50
18
10
8
1
1
1
1
1
1
2
3
1
1
1
1
1
1
1
1
2
2
3
10
10
10
10
10
10
20
30
10
10
10
10
10
10
10
10
20
20
30
12
12
12
12
12
12
24
36
12
12
12
12
12
12
12
12
24
24
36
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.150
0.050
0.050
0.070
0.070
0.075
0.080
0.090
0.100
0.100
0.125
0.150
0.05
0.08
0.10
0.11
0.14
0.20
0.29
0.34
0.05
0.05
0.07
0.08
0.10
0.11
0.12
0.16
0.20
0.25
0.32
0.05
0.08
0.09
0.10
0.13
0.18
0.26
0.31
0.04
0.05
0.06
0.07
0.09
0.10
0.11
0.14
0.18
0.23
0.28
0.02
0.03
0.04
0.04
0.06
0.08
0.12
0.14
0.02
0.02
0.03
0.03
0.04
0.04
0.05
0.06
0.08
0.10
0.13
0.95
0.84
0.77
0.72
0.64
0.50
0.43
0.44
1.05
0.92
0.99
0.92
0.77
0.75
0.73
0.63
0.50
0.50
0.47
0.85
0.75
0.70
0.65
0.57
0.45
0.39
0.40
0.94
0.83
0.89
0.82
0.70
0.67
0.66
0.57
0.45
0.45
0.43
0.38
0.33
0.31
0.29
0.25
0.20
0.17
0.18
0.42
0.37
0.40
0.37
0.31
0.30
0.29
0.25
0.20
0.20
0.19
6.5
4.5
2.5
1.5
1.3
22
17
14
12
8
7
6
4
2.5
2
F
G
H
A
A
B
B
C
D
E
F
F
G
H
0.1
0.15
0.22
0.33
0.47
0.68
1
1.5
2.2
3.3
4.7
1.5
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes.
NOTE: AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
10 ■ JUNE 2013