The Capacitor  
Table 2: MIL and EIA Temperature Stable and General Application Codes  
EIA CODE  
Percent Capacity Change Over Temperature Range  
MIL CODE  
Symbol  
Temperature Range  
RS198  
Temperature Range  
X7  
X5  
Y5  
Z5  
-55°C to +125°C  
-55°C to +85°C  
-30°C to +85°C  
+10°C to +85°C  
A
B
C
-55°C to +85°C  
-55°C to +125°C  
-55°C to +150°C  
Cap. Change  
Zero Volts  
Cap. Change  
Rated Volts  
Symbol  
Code  
Percent Capacity Change  
D
E
F
P
R
S
T
±3.3%  
±4.7%  
±7.5%  
±10%  
±15%  
R
W
X
+15%, -15%  
+22%, -56%  
+15%, -15%  
+30%, -70%  
+20%, -20%  
+15%, -40%  
+22%, -66%  
+15%, -25%  
+30%, -80%  
+20%, -30%  
±22%  
Y
+22%, -33%  
+22%, - 56%  
+22%, -82%  
U
V
Z
Temperature characteristic is specified by combining range and change  
symbols, for example BR or AW. Specification slash sheets indicate the  
characteristic applicable to a given style of capacitor.  
EXAMPLE – A capacitor is desired with the capacitance value at 25°C  
to increase no more than 7.5% or decrease no more than 7.5% from  
-30°C to +85°C. EIA Code will be Y5F.  
In specifying capacitance change with temperature for  
Class 2 materials, EIA expresses the capacitance change  
over an operating temperature range by a 3 symbol code.  
The first symbol represents the cold temperature end of the  
temperature range, the second represents the upper limit  
of the operating temperature range and the third symbol  
represents the capacitance change allowed over the  
operating temperature range. Table 2 provides a detailed  
explanation of the EIA system.  
reasonable range tends to increase both capacitance and  
dissipation factor readings. If a high enough AC voltage is  
applied, eventually it will reduce capacitance just as a DC  
voltage will. Figure 2 shows the effects of AC voltage.  
Capacitor specifications specify the AC voltage at which to  
measure (normally 0.5 or 1 VAC) and application of the  
wrong voltage can cause spurious readings. Figure 3 gives  
the voltage coefficient of dissipation factor for various AC  
voltages at 1 kilohertz. Applications of different frequencies  
will affect the percentage changes versus voltages.  
Effects of Voltage – Variations in voltage affects only the  
capacitance and dissipation factor. The application of DC  
voltage reduces both the capacitance and dissipation  
factor while the application of an AC voltage within a  
Cap. Change vs. A.C. Volts  
AVX X7R T.C.  
D.F. vs. A.C. Measurement Volts  
AVX X7R T.C.  
10.0  
50  
40  
30  
20  
Curve 1 - 100 VDC Rated Capacitor  
Curve 2 - 50 VDC Rated Capacitor  
Curve 3 - 25 VDC Rated Capacitor  
Curve 3  
Curve 2  
8.0  
6.0  
4.0  
Curve 1  
2.0  
0
10  
0
12.5  
25  
37.5  
50  
.5  
AC Measurement Volts at 1.0 KHz  
1.0  
1.5  
2.0  
2.5  
Volts AC at 1.0 KHz  
Figure 2  
Figure 3  
5
 复制成功!