X7R Dielectric “C”
GENERAL SPECIFICATIONS
TYPICAL CHARACTERISTICS
Capacitance Range
Temperature Coefficient
See Individual Parts Specifications
+12
+6
0
Capacitance Test at 25°C
Measured at 1 VRMS max. at 1 KHz
Capacitance Tolerances
J = ±5%, K = ±10%, M = ±20%
-6
Operating Temperature Range
-12
-18
-24
-55°C to +125°C
Temperature Characteristic
± 15% (0 Vdc)
-75 -50
0
+25 +50
+75 +100 +125
-25
Temperature °C
Voltage Ratings
200,100 & 50 Vdc
Dissipation Factor
∆ Capacitance vs. Frequency
2.5% max. at 1 KHz, 1 VRMS max.
Insulation Resistance 25°C (MIL-STD-202-Method 302)
100 K megohms or 1000 megohms - µF minimum,
whichever is less
+20
+10
0
Dielectric Strength
-10
-20
250% of rated Vdc
Life Test (1,000 hours)
200% rated voltage at +125°C
Moisture Resistance (MIL-STD-202-Method 106)
100 MHz
1 kHz
100 kHz
1 MHz
10 MHz
10 kHz
Frequency
Thermal Shock (MIL-STD-202-Method 107, condition A,
at rated elevated temperature)
Voltage Coefficient
-55°C to +125°C
+10
0
Immersion Cycling (MIL-STD-202-Method 104, condition B)
For current reliability information, consult factory.
100 Vdc Rated Parts
-10
-20
-30
-40
50/63 Rated Parts
100
60
40
D.C. Volts Applied
80
20
Insulation Resistance vs. Temp.
10,000
1,000
100
10
+20
+25 +40
+60 +80 +100
+150
Temperature °C
11