SMPS Stacked MLC Capacitors
SMX Style for High Temperature Applications up to 200ºC
ELECTRICAL SPECIFICATIONS
Temperature Coefficient
C0G:
A Temperature Coefficient
0
30 ppm/°C, -55° to +200°C
15ꢀ, -55°C to +125°C
X7R/X9U: C Temperature Coefficient
+15ꢀ - 56ꢀ, -55ºC to +200°C
Capacitance Test (MIL-STD-202 Method 305)
25°C, 1.0 0.2 Vrms (open circuit voltage) at 1KHz
Dissipation Factor 25°C
C0G:
0.15ꢀ Max @ 25°C, 1.0 0.2 Vrms (open circuit voltage) at 1KHz
X7R/X9U: 2.5ꢀ Max @ 25°C, 1.0 0.2 Vrms (open circuit voltage) at 1KHz
Insulation Resistance 25°C (MIL-STD-202 Method 302)
100K MΩ or 1000 MΩ-μF, whichever is less.
Insulation Resistance 125°C (MIL-STD-202 Method 302)
10K MΩ or 100 MΩ-μF, whichever is less.
Insulation Resistance 200°C (MIL-STD-202 Method 302)
100 MΩ or 1 MΩ -μF, whichever is less.
Dielectric Withstanding Voltage 25°C (Flash Test)
250ꢀ rated voltage for 5 seconds with 50 mA max
charging current. (500 Volt units @ 750 VDC)
Moisture Resistance (MIL-STD-202 Method 106)
Ten cycles with no voltage applied.
Thermal Shock (MIL-STD-202 Method 107, Condition A)
Immersion Cycling (MIL-STD-202 Method 104, Condition B)
Resistance To Solder Heat (MIL-STD-202, Method 210,
Condition B, for 20 seconds)
HOW TO ORDER
AVX Styles: SMX1, SMX2, SMX3, SMX4, SMX5, SMX6
SMX
1
7
C
106
M
A
N
650
AVX Style
SMX = Uncoated
Size
See
Dimensions
chart
Voltage Temperature
Capacitance
Code
Capacitance
Tolerance
C0G:
Test Level
A = Standard
Termination
N = Straight Lead
J = Leads formed in
L = Leads formed out
P = P Style Leads
Z = Z Style Leads
Height
Max
25 = 3 Coefficient
50V = 5
C0G = A (2 significant digits
Dimension “A”
120 = 0.120"
240 = 0.240"
360 = 0.360"
480 = 0.480"
650 = 0.650"
100V = 1 X7R/X9U = C + number of zeros)
J = 5ꢀ
200V = 2
500V = 7
10 pF = 100
100 pF = 101
1,000 pF = 102
22,000 pF = 223
220,000 pF = 224
1μF = 105
K = 10ꢀ
M = 20ꢀ
X7R:
K = 10ꢀ
M = 20ꢀ
Z = +80ꢀ, -20ꢀ
10 μF = 106
100 μF = 107
Note: Capacitors with X7R/X9U dielectric is not intended for applications across AC supply mains or AC line filtering with polarity reversal. Contact plant for recommendations.