 浏览型号M49470Q01185KEJ的Datasheet PDF文件第64页浏览型号M49470Q01185KEJ的Datasheet PDF文件第65页浏览型号M49470Q01185KEJ的Datasheet PDF文件第66页浏览型号M49470Q01185KEJ的Datasheet PDF文件第67页浏览型号M49470Q01185KEJ的Datasheet PDF文件第69页浏览型号M49470Q01185KEJ的Datasheet PDF文件第70页浏览型号M49470Q01185KEJ的Datasheet PDF文件第71页浏览型号M49470Q01185KEJ的Datasheet PDF文件第72页  
Surface Mounting Guide  
MLC Chip Capacitors  
POST SOLDER HANDLING  
COMMON CAUSES OF  
Once SMP components are soldered to the board, any  
bending or flexure of the PCB applies stresses to the soldered  
joints of the components. For leaded devices, the stresses are  
absorbed by the compliancy of the metal leads and generally  
don’t result in problems unless the stress is large enough to  
fracture the soldered connection.  
MECHANICAL CRACKING  
The most common source for mechanical stress is board  
depanelization equipment, such as manual breakapart,  
v-cutters and shear presses. Improperly aligned or dull cutters  
may cause torqueing of the PCB resulting in flex stresses  
being transmitted to components near the board edge.  
Another common source of flexural stress is contact during  
parametric testing when test points are probed. If the PCB  
is allowed to flex during the test cycle, nearby ceramic  
capacitors may be broken.  
Ceramic capacitors are more susceptible to such stress  
because they don’t have compliant leads and are brittle in  
nature. The most frequent failure mode is low DC resistance or  
short circuit. The second failure mode is significant loss of  
capacitance due to severing of contact between sets of the  
internal electrodes.  
A third common source is board to board connections at  
vertical connectors where cables or other PCBs are con-  
nected to the PCB. If the board is not supported during the  
plug/unplug cycle, it may flex and cause damage to nearby  
components.  
Cracks caused by mechanical flexure are very easily identified  
and generally take one of the following two general forms:  
Special care should also be taken when handling large (>6"  
on a side) PCBs since they more easily flex or warp than  
smaller boards.  
REWORKING OF MLCs  
Thermal shock is common in MLCs that are manually  
attached or reworked with a soldering iron. AVX strongly  
recommends that any reworking of MLCs be done with hot  
air reflow rather than soldering irons. It is practically impossible  
to cause any thermal shock in ceramic capacitors when  
using hot air reflow.  
Type A:  
Angled crack between bottom of device to top of solder joint.  
However direct contact by the soldering iron tip often causes  
thermal cracks that may fail at a later date. If rework by  
soldering iron is absolutely necessary, it is recommended  
that the wattage of the iron be less than 30 watts and the  
tip temperature be <300ºC. Rework should be performed  
by applying the solder iron tip to the pad and not directly  
contacting any part of the ceramic capacitor.  
Type B:  
Fracture from top of device to bottom of device.  
Mechanical cracks are often hidden underneath the termina-  
tion and are difficult to see externally. However, if one end  
termination falls off during the removal process from PCB,  
this is one indication that the cause of failure was excessive  
mechanical stress due to board warping.  
67