欢迎访问ic37.com |
会员登录 免费注册
发布采购

DB0805A1950AWTR 参数 Datasheet PDF下载

DB0805A1950AWTR图片预览
型号: DB0805A1950AWTR
PDF下载: 下载PDF文件 查看货源
内容描述: 薄膜定向耦合器 [Thin-Film Directional Couplers]
分类和应用:
文件页数/大小: 13 页 / 100 K
品牌: KYOCERA AVX [ KYOCERA AVX ]
 浏览型号DB0805A1950AWTR的Datasheet PDF文件第5页浏览型号DB0805A1950AWTR的Datasheet PDF文件第6页浏览型号DB0805A1950AWTR的Datasheet PDF文件第7页浏览型号DB0805A1950AWTR的Datasheet PDF文件第8页浏览型号DB0805A1950AWTR的Datasheet PDF文件第9页浏览型号DB0805A1950AWTR的Datasheet PDF文件第10页浏览型号DB0805A1950AWTR的Datasheet PDF文件第11页浏览型号DB0805A1950AWTR的Datasheet PDF文件第12页  
Thin-Film Directional Couplers  
DB0805 3dB 90° Test Jigs  
GENERAL DESCRIPTION  
These jigs are designed for testing the DB0805 3dB 90°  
Couplers using a Vector Network Analyzer.  
The connectors are SMA type (female), ‘Johnson Components  
Inc.’ Product P/N: 142-0701-841.  
They consist of a dielectric substrate, having 50microstrips  
as conducting lines and a bottom ground plane located at a  
distance of 0.254mm from the microstrips.  
Both a measurement jig and a calibration jig are provided.  
The calibration jig is designed for a full 2-port calibration, and  
consists of an open line, short line and through line. LOAD  
calibration can be done by a 50SMA termination.  
The substrate used is Neltecs NH9338ST0254C1BC.  
MEASUREMENT PROCEDURE  
When measuring a component, it can be either soldered or  
pressed using a non-metallic stick until all four ports touch  
the appropriate pads. Set the VNA to the relevant frequency  
band. Connect the VNA using a 10dB attenuator on the jig  
terminal connected to port 2. Follow the VNAs instruction  
manual and use the calibration jig to perform a full 2-port  
calibration in the required bandwidths.  
Place the coupler on the measurement jig as follows:  
3
Input (Coupler) Connector 1 (Jig)  
50(Coupler) Connector 2 (Jig)  
Output 1 (Coupler) Connector 3 (Jig)  
Output 2 (Coupler) Connector 4 (Jig)  
To measure R. Loss and I. Loss 1 connect:  
Connector 1 (Jig) Port 1 (VNA) Connector 3 (Jig) Port 2 (VNA)  
Connector 2 (Jig) 50Ω  
Connector 4 (Jig) 50Ω  
To measure R. Loss and I. Loss 2 connect:  
Connector 1 (Jig) Port 1 (VNA) Connector 3 (Jig) 50Ω  
Connector 2 (Jig) 50Ω  
Connector 4 (Jig) Port 2 (VNA)  
To measure Isolation connect:  
Connector 1 (Jig) 50Ω  
Connector 3 (Jig) Port 1 (VNA)  
Connector 4 (Jig) Port 2 (VNA)  
Connector 2 (Jig) 50Ω  
Calibration Jig  
Measurement Jig  
Connector ꢀ  
Load &  
Through  
Connector  
Johnson  
P/N ꢀꢁ2-070ꢀ-8ꢁꢀ  
Connector 2  
Load &  
Through  
Connector ꢁ  
Short Line  
to GND  
Open  
Line  
Connector 3  
65