X7R Dielectric “C”
GENERAL SPECIFICATIONS
Capacitance Range
See Individual Parts Specifications
Capacitance Test at 25°C
Measured at 1 VRMS max. at 1 KHz
Capacitance
+12
+6
0
-6
-12
-18
-24
-75
-50
-25
0 +25 +50 +75 +100 +125
Temperature
°C
TYPICAL CHARACTERISTICS
Temperature Coefficient
Capacitance Tolerances
J = ±5%, K = ±10%, M = ±20%
Operating Temperature Range
-55°C to +125°C
Temperature Characteristic
± 15% (0 Vdc)
Voltage Ratings
200,100 & 50 Vdc
Dissipation Factor
2.5% max. at 1 KHz, 1 VRMS max.
Insulation Resistance 25°C (MIL-STD-202-Method 302)
100 K megohms or 1000 megohms - µF minimum,
whichever is less
Dielectric Strength
250% of rated Vdc
Life Test (1,000 hours)
200% rated voltage at +125°C
Moisture Resistance (MIL-STD-202-Method 106)
Thermal Shock (MIL-STD-202-Method 107, condition A,
at rated elevated temperature)
-55°C to +125°C
Immersion Cycling (MIL-STD-202-Method 104, condition B)
For current reliability information, consult factory.
%
∆
Capacitance vs. Frequency
+20
Capacitance
%
-20
+10
0
-10
1 kHz
10 kHz
100 kHz
1 MHz
Frequency
10 MHz
100 MHz
Voltage Coefficient
+10
0
Capacitance
-10
-20
-30
-40
100 Vdc Rated Parts
50/63 Rated Parts
%
20
40
60
80
100
D.C. Volts Applied
Insulation Resistance vs. Temp.
10,000
Insulation Resistance (Ohm-Farads)
1,000
100
10
+20
+25
+40
+60 +80 +100
Temperature
°C
+150
11